• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Dosimetric and biologic intercomparison between electron and proton FLASH beams.
 

Dosimetric and biologic intercomparison between electron and proton FLASH beams.

Options
  • Details
BORIS DOI
10.48350/187209
Date of Publication
January 2024
Publication Type
Article
Division/Institute

Paul Scherrer Institu...

Contributor
Almeida, A
Togno, M
Ballesteros-Zebadua, P
Franco-Perez, J
Geyer, R
Schaefer, R
Petit, B
Grilj, V
Meer, D
Safai, S
Lomax, T
Weber, Damien Charles
Paul Scherrer Institut
Universitätsklinik für Radio-Onkologie
Bailat, C
Psoroulas, S
Vozenin, M C
Subject(s)

600 - Technology::610...

Series
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
ISSN or ISBN (if monograph)
1879-0887
Publisher
Elsevier Scientific Publ. Ireland
Language
English
Publisher DOI
10.1016/j.radonc.2023.109953
PubMed ID
37839557
Description
BACKGROUND AND PURPOSE

The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at an average dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by eFLASHvs. pFLASH has yet been performed and constitutes the aim of the present study.

MATERIALS AND METHODS

The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥110 Gy/s eFLASH and pFLASH) dose rates. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed using previously validated dosimetric approaches and experimental murine models.

RESULTS

The difference between the average absorbed dose measured at Gantry 1 with PSI reference dosimeters and with CHUV/IRA dosimeters was -1.9 % (0.1 Gy/s) and +2.5 % (110 Gy/s). The neurocognitive capacity of eFLASH and pFLASH irradiated mice was indistinguishable from the control, while both eCONV and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained after an ablative dose of 20 Gy delivered with the two beams at CONV and FLASH dose rates. Tumor rejection upon rechallenge indicates that anti-tumor immunity was activated independently of the beam-type and the dose-rate.

CONCLUSION

Despite major differences in the temporal microstructure of proton and electron beams, this study shows that dosimetric standards can be established. Normal brain protection and tumor control were produced by the two beams. More specifically, normal brain protection was achieved when a single dose of 10 Gy was delivered in 90 milliseconds or less, suggesting that the most important physical parameter driving the FLASH sparing effect might be the mean dose rate. In addition, a systemic anti-tumor immunological memory response was observed in mice exposed to high ablative dose of electron and proton delivered at CONV and FLASH dose rate.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/190610
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
1-s2.0-S0167814023898474-main.pdftextAdobe PDF2.05 MBpublisheracceptedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 960e9e [21.08. 13:49]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo