• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Dorsal Cortical Screw Penetration in Volar Distal Radius Plating: Comparison of 3 Fluoroscopic Views.
 

Dorsal Cortical Screw Penetration in Volar Distal Radius Plating: Comparison of 3 Fluoroscopic Views.

Options
  • Details
BORIS DOI
10.48620/77360
Date of Publication
November 2024
Publication Type
Article
Division/Institute

Clinic of Intensive C...

Contributor
Guidi, Marco
Previ, Leonardo
Mazza, Daniele
Lucchina, Stefano
Fusetti, Cesare
Goldshmidt, Shahar Beni
Di Maro, Agostino
Uccheddu, Graziano
Mantini, Vito
Bruno, Jolie
Clinic of Intensive Care Medicine
Riegger, Martin
Subject(s)

600 - Technology::610...

Series
Plastic and Reconstructive Surgery Global Open
ISSN or ISBN (if monograph)
2169-7574
Publisher
Lippincott, Williams & Wilkins
Language
English
Publisher DOI
10.1097/GOX.0000000000006320
PubMed ID
39534371
Description
Background
The skyline or dorsal tangential view (DTV) and the carpal shoot-through (CST) have been developed to enhance the intraoperative examination of the distal radius's dorsal cortex during open reduction and internal fixation with volar plates. This study aimed to assess the lateral view (LV), DTV, and CST's effectiveness in showcasing screws that penetrate the dorsal cortex.
Methods
Eighty patients, comprised of 42 women and 38 men with an average age of 53 years, underwent volar locking plate fixation for displaced distal radius fractures. The procedures incorporated the use of intraoperative LV, DTV, and CST views. Every view was meticulously examined to record the presence of screws that breached the dorsal cortex of the fractured region.
Results
Only 2 screws were found to protrude the dorsal cortex in the LV, demonstrating 100% specificity and 18.8% sensitivity. On the DTV, 9 screws were detected with the same specificity but increased sensitivity (75%). On the CST, all 12 screws were identified, making for 100% specificity and sensitivity. Of 501 distal screws, 13 (2.54%) penetrated the dorsal cortex, with an average length of 1.34 mm (range, 0.5-2 mm). These screws were subsequently replaced with shorter screws in 12 of 80 patients.
Conclusions
The findings show that the CST and DTV are more precise and accurate than LV in identifying dorsal screw protrusion during distal radius volar plating. To minimize the likelihood of subsequent complications, it is highly advisable to implement these views in all procedures.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/189605
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
dorsal_cortical_screw_penetration_in_volar_distal.28.pdftextAdobe PDF1.1 MBAttribution-NonCommercial-NoDerivatives (CC BY-NC-ND 4.0)publishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 960e9e [21.08. 13:49]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo