Publication:
Dorsal Cortical Screw Penetration in Volar Distal Radius Plating: Comparison of 3 Fluoroscopic Views.

cris.virtualsource.author-orcid5b77948c-ceeb-49be-9927-c387dd111adc
datacite.rightsopen.access
dc.contributor.authorGuidi, Marco
dc.contributor.authorPrevi, Leonardo
dc.contributor.authorMazza, Daniele
dc.contributor.authorLucchina, Stefano
dc.contributor.authorFusetti, Cesare
dc.contributor.authorGoldshmidt, Shahar Beni
dc.contributor.authorDi Maro, Agostino
dc.contributor.authorUccheddu, Graziano
dc.contributor.authorMantini, Vito
dc.contributor.authorBruno, Jolie
dc.contributor.authorRiegger, Martin
dc.date.accessioned2024-12-11T08:21:43Z
dc.date.available2024-12-11T08:21:43Z
dc.date.issued2024-11
dc.description.abstractBackground The skyline or dorsal tangential view (DTV) and the carpal shoot-through (CST) have been developed to enhance the intraoperative examination of the distal radius's dorsal cortex during open reduction and internal fixation with volar plates. This study aimed to assess the lateral view (LV), DTV, and CST's effectiveness in showcasing screws that penetrate the dorsal cortex. Methods Eighty patients, comprised of 42 women and 38 men with an average age of 53 years, underwent volar locking plate fixation for displaced distal radius fractures. The procedures incorporated the use of intraoperative LV, DTV, and CST views. Every view was meticulously examined to record the presence of screws that breached the dorsal cortex of the fractured region. Results Only 2 screws were found to protrude the dorsal cortex in the LV, demonstrating 100% specificity and 18.8% sensitivity. On the DTV, 9 screws were detected with the same specificity but increased sensitivity (75%). On the CST, all 12 screws were identified, making for 100% specificity and sensitivity. Of 501 distal screws, 13 (2.54%) penetrated the dorsal cortex, with an average length of 1.34 mm (range, 0.5-2 mm). These screws were subsequently replaced with shorter screws in 12 of 80 patients. Conclusions The findings show that the CST and DTV are more precise and accurate than LV in identifying dorsal screw protrusion during distal radius volar plating. To minimize the likelihood of subsequent complications, it is highly advisable to implement these views in all procedures.
dc.description.numberOfPages7
dc.description.sponsorshipClinic of Intensive Care Medicine
dc.identifier.doi10.48620/77360
dc.identifier.pmid39534371
dc.identifier.publisherDOI10.1097/GOX.0000000000006320
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/189605
dc.language.isoen
dc.publisherLippincott, Williams & Wilkins
dc.relation.ispartofPlastic and Reconstructive Surgery Global Open
dc.relation.issn2169-7574
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleDorsal Cortical Screw Penetration in Volar Distal Radius Plating: Comparison of 3 Fluoroscopic Views.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue11
oaire.citation.startPagee6320
oaire.citation.volume12
oairecerif.author.affiliationClinic of Intensive Care Medicine
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.description.ispublishedpub
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
dorsal_cortical_screw_penetration_in_volar_distal.28.pdf
Size:
1.1 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by-nc-nd/4.0
Content:
published

Collections