  3. Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study
 

Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study

Options
  • Details
BORIS DOI
10.48350/164747
Date of Publication
February 2021
Publication Type
Article
Division/Institute

Departement für klini...

Author
Mariani, Christopher
Zlotnick, Joshua
Harrysson, Ola
Marcellin-Little, Denis
Malinak, Kristen
Gavitt, Ashley
Guevar, Julien Jean
Departement für klinische Veterinärmedizin, Kleintierklinik
Subject(s)

500 - Science::570 - ...

500 - Science::590 - ...

600 - Technology::610...

Series
Veterinary surgery
ISSN or ISBN (if monograph)
0161-3499
Publisher
Wiley-Blackwell
Language
English
Publisher DOI
10.1111/vsu.13557
PubMed ID
33373470
Description
Objective: To assess the accuracy of three-dimensionally (3-D) printed drill guides in constraining the trajectory of drill tracts for implants in canine thoracic vertebrae.

Study design: Experimental ex vivo study.

Sample population: Five canine thoracic vertebral column specimens.

Methods: Guides to constrain drill trajectories were designed on the basis of computed tomographic (CT) imaging of six thoracic vertebrae (T8-T13) and were 3-D printed. The guides were used to create drill tracts in these vertebrae by both an experienced and a novice surgeon, and CT imaging was repeated. The entry point and angulation of actual and planned drill tracts were compared for both surgeons. Unintended cortical violations were also assessed by using a modified Zdichavsky classification.

Results: Fifty-eight drill tracts were created in 30 vertebrae. Mean entry point deviation was 1.4 mm (range, 0.4-3.4), and mean angular deviation was 5.1° (range, 1.5°-10.8°). There were no differences between surgeons in entry point deviation (P = .07) or angular deviation (P = .22). There were no unintended cortical bone violations, and all drill tracts were classified as modified Zdichavsky grade I.

Conclusion: The 3-D printed guides used in the current study yielded drill tracts with small linear and angular errors from intended paths and 100% accuracy for placement within vertebral pedicles and bodies. This technique was conveniently used by both an experienced and a novice surgeon.

Clinical significance: This technique might be immediately applicable to clinical cases requiring thoracic vertebral stabilization and may allow safe and accurate implant placement for surgeons with varying experience levels.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/66935
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Veterinary Surgery - 2021 - Mariani - Accuracy of three%u2010dimensionally printed animal%u2010specific drill guides for implant.pdftextAdobe PDF1.8 MBpublisherpublished restricted
BORIS Portal
Bern Open Repository and Information System
Build: b407eb [23.05. 15:47]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo