Publication:
Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study

cris.virtualsource.author-orcidfa05c2d1-b135-4968-aa3a-ab48a6bee6d3
datacite.rightsrestricted
dc.contributor.authorMariani, Christopher
dc.contributor.authorZlotnick, Joshua
dc.contributor.authorHarrysson, Ola
dc.contributor.authorMarcellin-Little, Denis
dc.contributor.authorMalinak, Kristen
dc.contributor.authorGavitt, Ashley
dc.contributor.authorGuevar, Julien Jean
dc.date.accessioned2024-10-09T15:16:28Z
dc.date.available2024-10-09T15:16:28Z
dc.date.issued2021-02
dc.description.abstractObjective: To assess the accuracy of three-dimensionally (3-D) printed drill guides in constraining the trajectory of drill tracts for implants in canine thoracic vertebrae. Study design: Experimental ex vivo study. Sample population: Five canine thoracic vertebral column specimens. Methods: Guides to constrain drill trajectories were designed on the basis of computed tomographic (CT) imaging of six thoracic vertebrae (T8-T13) and were 3-D printed. The guides were used to create drill tracts in these vertebrae by both an experienced and a novice surgeon, and CT imaging was repeated. The entry point and angulation of actual and planned drill tracts were compared for both surgeons. Unintended cortical violations were also assessed by using a modified Zdichavsky classification. Results: Fifty-eight drill tracts were created in 30 vertebrae. Mean entry point deviation was 1.4 mm (range, 0.4-3.4), and mean angular deviation was 5.1° (range, 1.5°-10.8°). There were no differences between surgeons in entry point deviation (P = .07) or angular deviation (P = .22). There were no unintended cortical bone violations, and all drill tracts were classified as modified Zdichavsky grade I. Conclusion: The 3-D printed guides used in the current study yielded drill tracts with small linear and angular errors from intended paths and 100% accuracy for placement within vertebral pedicles and bodies. This technique was conveniently used by both an experienced and a novice surgeon. Clinical significance: This technique might be immediately applicable to clinical cases requiring thoracic vertebral stabilization and may allow safe and accurate implant placement for surgeons with varying experience levels.
dc.description.numberOfPages9
dc.description.sponsorshipDepartement für klinische Veterinärmedizin, Kleintierklinik
dc.identifier.doi10.48350/164747
dc.identifier.pmid33373470
dc.identifier.publisherDOI10.1111/vsu.13557
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/66935
dc.language.isoen
dc.publisherWiley-Blackwell
dc.relation.ispartofVeterinary surgery
dc.relation.issn0161-3499
dc.relation.organizationDCD5A442BFE1E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C034E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C049E17DE0405C82790C4DE2
dc.subject.ddc500 - Science::570 - Life sciences; biology
dc.subject.ddc500 - Science::590 - Animals (Zoology)
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleAccuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage302
oaire.citation.issue2
oaire.citation.startPage294
oaire.citation.volume50
oairecerif.author.affiliationDepartement für klinische Veterinärmedizin, Kleintierklinik
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2022-02-10 14:14:41
unibe.description.ispublishedpub
unibe.eprints.legacyId164747
unibe.journal.abbrevTitleVET SURG
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Veterinary Surgery - 2021 - Mariani - Accuracy of three%u2010dimensionally printed animal%u2010specific drill guides for implant.pdf
Size:
1.8 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections