• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Research Data
  • Organizations
  • Researchers
  • More
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study
 

Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study

Options
  • Details
  • Files
BORIS DOI
10.48350/164747
Publisher DOI
10.1111/vsu.13557
PubMed ID
33373470
Description
Objective: To assess the accuracy of three-dimensionally (3-D) printed drill guides in constraining the trajectory of drill tracts for implants in canine thoracic vertebrae.

Study design: Experimental ex vivo study.

Sample population: Five canine thoracic vertebral column specimens.

Methods: Guides to constrain drill trajectories were designed on the basis of computed tomographic (CT) imaging of six thoracic vertebrae (T8-T13) and were 3-D printed. The guides were used to create drill tracts in these vertebrae by both an experienced and a novice surgeon, and CT imaging was repeated. The entry point and angulation of actual and planned drill tracts were compared for both surgeons. Unintended cortical violations were also assessed by using a modified Zdichavsky classification.

Results: Fifty-eight drill tracts were created in 30 vertebrae. Mean entry point deviation was 1.4 mm (range, 0.4-3.4), and mean angular deviation was 5.1° (range, 1.5°-10.8°). There were no differences between surgeons in entry point deviation (P = .07) or angular deviation (P = .22). There were no unintended cortical bone violations, and all drill tracts were classified as modified Zdichavsky grade I.

Conclusion: The 3-D printed guides used in the current study yielded drill tracts with small linear and angular errors from intended paths and 100% accuracy for placement within vertebral pedicles and bodies. This technique was conveniently used by both an experienced and a novice surgeon.

Clinical significance: This technique might be immediately applicable to clinical cases requiring thoracic vertebral stabilization and may allow safe and accurate implant placement for surgeons with varying experience levels.
Date of Publication
2021-02
Publication Type
Article
Subject(s)
500 - Science::570 - Life sciences; biology
500 - Science::590 - Animals (Zoology)
600 - Technology::610 - Medicine & health
Language(s)
en
Contributor(s)
Mariani, Christopher
Zlotnick, Joshua
Harrysson, Ola
Marcellin-Little, Denis
Malinak, Kristen
Gavitt, Ashley
Guevar, Julien Jean
Departement für klinische Veterinärmedizin, Kleintierklinik
Additional Credits
Departement für klinische Veterinärmedizin, Kleintierklinik
Series
Veterinary surgery
Publisher
Wiley-Blackwell
ISSN
0161-3499
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: ae9592 [15.12. 16:43]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo