  3. In Vitro and In Vivo Imaging Characteristics Assessment of Polymeric Coils Compared with Standard Platinum Coils for the Treatment of Intracranial Aneurysms
 

In Vitro and In Vivo Imaging Characteristics Assessment of Polymeric Coils Compared with Standard Platinum Coils for the Treatment of Intracranial Aneurysms

Options
  • Details
BORIS DOI
10.7892/boris.15729
Date of Publication
November 2013
Publication Type
Article
Division/Institute

ARTORG Center - Cardi...

Departement Klinische...

Institut für Diagnost...

Universitätsinstitut ...

Universitätsklinik fü...

Author
Mordasini, Pasquale Renato
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Krähenbühl, Anna Katharina
Universitätsklinik für Neurochirurgie
Byrne, J. V.
Vandenberghe, Stijn
ARTORG Center - Cardiovascular Engineering (Heart)
Reinert, Michael
Departement Klinische Forschung, Forschungsgruppe Neurochirurgie
Hoppe, Hanno
Institut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Gralla, Jan
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Subject(s)

600 - Technology::610...

Series
American journal of neuroradiology AJNR
ISSN or ISBN (if monograph)
0195-6108
Publisher
American Society of Neuroradiology
Language
English
Publisher DOI
10.3174/ajnr.A3589
PubMed ID
23721897
Description
BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/89776
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
2177.full.pdftextAdobe PDF1.39 MBpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: d1c7f7 [27.06. 13:56]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo