Publication:
In Vitro and In Vivo Imaging Characteristics Assessment of Polymeric Coils Compared with Standard Platinum Coils for the Treatment of Intracranial Aneurysms

cris.virtualsource.author-orcid29e771f2-4628-4190-b532-748410b5aff5
cris.virtualsource.author-orcid21c23f9e-029e-42fe-b45d-e8ac6707f465
cris.virtualsource.author-orcidc4624c56-a849-47d1-8c51-07a75708947b
cris.virtualsource.author-orcid9d3bfb42-afb9-48a6-a36d-7bca8936b3a4
cris.virtualsource.author-orcid3bbfb2a9-e0a0-41d6-bf5b-df47b5069dc7
cris.virtualsource.author-orcid6bca269a-b080-43cf-a340-2559fc2f7595
datacite.rightsopen.access
dc.contributor.authorMordasini, Pasquale Renato
dc.contributor.authorKrähenbühl, Anna Katharina
dc.contributor.authorByrne, J. V.
dc.contributor.authorVandenberghe, Stijn
dc.contributor.authorReinert, Michael
dc.contributor.authorHoppe, Hanno
dc.contributor.authorGralla, Jan
dc.date.accessioned2024-10-13T13:03:03Z
dc.date.available2024-10-13T13:03:03Z
dc.date.issued2013-11
dc.description.abstractBACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.
dc.description.numberOfPages7
dc.description.sponsorshipARTORG Center - Cardiovascular Engineering (Heart)
dc.description.sponsorshipDepartement Klinische Forschung, Forschungsgruppe Neurochirurgie
dc.description.sponsorshipInstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
dc.description.sponsorshipUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
dc.description.sponsorshipUniversitätsklinik für Neurochirurgie
dc.identifier.doi10.7892/boris.15729
dc.identifier.pmid23721897
dc.identifier.publisherDOI10.3174/ajnr.A3589
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/89776
dc.language.isoen
dc.publisherAmerican Society of Neuroradiology
dc.publisher.placeOak Brook, Ill.
dc.relation.ispartofAmerican journal of neuroradiology AJNR
dc.relation.issn0195-6108
dc.relation.organizationDCD5A442C057E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C011E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BB1CE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C4C7E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C499E17DE0405C82790C4DE2
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleIn Vitro and In Vivo Imaging Characteristics Assessment of Polymeric Coils Compared with Standard Platinum Coils for the Treatment of Intracranial Aneurysms
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage2183
oaire.citation.issue11
oaire.citation.startPage2177
oaire.citation.volume34
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
oairecerif.author.affiliationUniversitätsklinik für Neurochirurgie
oairecerif.author.affiliationARTORG Center - Cardiovascular Engineering (Heart)
oairecerif.author.affiliationDepartement Klinische Forschung, Forschungsgruppe Neurochirurgie
oairecerif.author.affiliationInstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.description.ispublishedpub
unibe.eprints.legacyId15729
unibe.journal.abbrevTitleAM J NEURORADIOL
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
2177.full.pdf
Size:
1.39 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections