• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Effect of voxel size in cone-beam computed tomography on surface area measurements of dehiscences and fenestrations in the lower anterior buccal region.
 

Effect of voxel size in cone-beam computed tomography on surface area measurements of dehiscences and fenestrations in the lower anterior buccal region.

Options
  • Details
BORIS DOI
10.48350/169846
Date of Publication
September 2022
Publication Type
Article
Division/Institute

Zahnmedizinische Klin...

Contributor
van Leeuwen, B J
Dijkstra, P U
Dieters, J A
Verbeek, H P J
Kuijpers-Jagtman, Anne-Marie
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie
Ren, Y
Subject(s)

600 - Technology::610...

Series
Clinical oral investigations
ISSN or ISBN (if monograph)
1436-3771
Publisher
Springer
Language
English
Publisher DOI
10.1007/s00784-022-04521-x
PubMed ID
35513582
Uncontrolled Keywords

Accuracy Cone-beam co...

Description
OBJECTIVES

This study aims to assess whether different voxel sizes in cone-beam computed tomography (CBCT) affected surface area measurements of dehiscences and fenestrations in the mandibular anterior buccal region.

MATERIALS AND METHODS

Nineteen dry human mandibles were scanned with a surface scanner (SS). Wax was attached to the mandibles as a soft tissue equivalent. Three-dimensional digital models were generated with a CBCT unit, with voxel sizes of 0.200 mm (VS200), 0.400 mm (VS400), and 0.600 mm (VS600). The buccal surface areas of the six anterior teeth were measured (in mm2) to evaluate areas of dehiscences and fenestrations. Differences between the CBCT and SS measurements were determined in a linear mixed model analysis.

RESULTS

The mean surface area per tooth was 88.3 ± 24.0 mm2, with the SS, and 94.6 ± 26.5 (VS200), 95.1 ± 27.3 (VS400), and 96.0 ± 26.5 (VS600), with CBCT scans. Larger surface areas resulted in larger differences between CBCT and SS measurements (- 0.1 β, SE = 0.02, p < 0.001). Deviations from SS measurements were larger with VS600, compared to VS200 (1.3 β, SE = 0.05, P = 0.009). Fenestrations were undetectable with CBCT.

CONCLUSIONS

CBCT imaging magnified the surface area of dehiscences in the anterior buccal region of the mandible by 7 to 9%. The larger the voxel size, the larger the deviation from SS measurements. Fenestrations were not detectable with CBCT.

CLINICAL RELEVANCE

CBCT is an acceptable tool for measuring dehiscences but not fenestrations. However, CBCT overestimates the size of dehiscences, and the degree of overestimation depends on the actual dehiscence size and CBCT voxel size employed.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/70644
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Leeuwen2022_Article_EffectOfVoxelSizeInCone-beamCo.pdftextAdobe PDF1.17 MBAttribution (CC BY 4.0)publishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 27ad28 [15.10. 15:21]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo