1-Year Outcomes With the Evolut R Self-Expanding Transcatheter Aortic Valve: From the International FORWARD Study.
Options
BORIS DOI
Date of Publication
November 26, 2018
Publication Type
Article
Division/Institute
Author
Manoharan, Ganesh | |
Van Mieghem, Nicolas M | |
Bosmans, Johan | |
Bleiziffer, Sabine | |
Modine, Thomas | |
Linke, Axel | |
Scholtz, Werner | |
Chevalier, Bernard | |
Gooley, Robert | |
Zeng, Cathy | |
Oh, Jae K | |
Grube, Eberhard |
Subject(s)
Series
JACC. Cardiovascular Interventions
ISSN or ISBN (if monograph)
1876-7605
Publisher
Elsevier
Language
English
Publisher DOI
PubMed ID
30466832
Uncontrolled Keywords
Description
OBJECTIVES
This study sought to report the 1-year safety and efficacy outcomes in the FORWARD (CoreValve Evolut R FORWARD) study following transcatheter aortic valve replacement (TAVR) with the next-generation Evolut R device (Medtronic, Minneapolis, Minnesota) in routine clinical practice.
BACKGROUND
The FORWARD study reported low incidences of mortality, disabling stroke, and significant paravalvular leak following TAVR in routine clinical practice at 30 days. Longer-term results in large patient populations with the Evolut R self-expanding, repositionable transcatheter heart valve (THV) are lacking.
METHODS
This was a prospective, single-arm, multinational, multicenter, observational study investigating efficacy and safety following TAVR with the next-generation self-expanding THV. Between January and December 2016, 1,040 patients underwent attempted implant of the Evolut R self-expanding repositionable valve at 53 sites worldwide. An independent Clinical Events Committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms.
RESULTS
The mean age was 81.8 ± 6.2 years, 64.8% were women, and patients had a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.5 ± 4.5% and EuroSCORE II of 5.7 ± 5.0%. The 1-year all-cause mortality rate was 8.9%, with a cardiovascular mortality rate of 6.9%. At 1 year, the incidence of disabling stroke was 2.1%, and a pacemaker was implanted in 19.7% of patients. The incidence of more than mild paravalvular leak was 1.2%.
CONCLUSIONS
The FORWARD study demonstrated good safety and efficacy profiles for the next-generation Evolut R THV up to 1-year follow-up, with very low mortality and adverse events. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369).
This study sought to report the 1-year safety and efficacy outcomes in the FORWARD (CoreValve Evolut R FORWARD) study following transcatheter aortic valve replacement (TAVR) with the next-generation Evolut R device (Medtronic, Minneapolis, Minnesota) in routine clinical practice.
BACKGROUND
The FORWARD study reported low incidences of mortality, disabling stroke, and significant paravalvular leak following TAVR in routine clinical practice at 30 days. Longer-term results in large patient populations with the Evolut R self-expanding, repositionable transcatheter heart valve (THV) are lacking.
METHODS
This was a prospective, single-arm, multinational, multicenter, observational study investigating efficacy and safety following TAVR with the next-generation self-expanding THV. Between January and December 2016, 1,040 patients underwent attempted implant of the Evolut R self-expanding repositionable valve at 53 sites worldwide. An independent Clinical Events Committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms.
RESULTS
The mean age was 81.8 ± 6.2 years, 64.8% were women, and patients had a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.5 ± 4.5% and EuroSCORE II of 5.7 ± 5.0%. The 1-year all-cause mortality rate was 8.9%, with a cardiovascular mortality rate of 6.9%. At 1 year, the incidence of disabling stroke was 2.1%, and a pacemaker was implanted in 19.7% of patients. The incidence of more than mild paravalvular leak was 1.2%.
CONCLUSIONS
The FORWARD study demonstrated good safety and efficacy profiles for the next-generation Evolut R THV up to 1-year follow-up, with very low mortality and adverse events. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369).
File(s)
File | File Type | Format | Size | License | Publisher/Copright statement | Content | |
---|---|---|---|---|---|---|---|
1-Year outcomes With the Evolut.pdf | text | Adobe PDF | 821.69 KB | publisher | published |