• LOGIN
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publication
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Basic concepts in metal work failure after metastatic spine tumour surgery.
 

Basic concepts in metal work failure after metastatic spine tumour surgery.

Options
  • Details
BORIS DOI
10.7892/boris.109973
Date of Publication
April 2018
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Author
Kumar, Naresh
Patel, Ravish
Wadhwa, Anshuja Charvi
Kumar, Aravind
Milavec, Helena Maria
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Sonawane, Dhiraj
Singh, Gurpal
Benneker, Lorin Michael
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Subject(s)

600 - Technology::610...

Series
European spine journal
ISSN or ISBN (if monograph)
0940-6719
Publisher
Springer
Language
English
Publisher DOI
10.1007/s00586-017-5405-z
PubMed ID
29204734
Uncontrolled Keywords

Asymptomatic implant ...

Description
PURPOSE

The development of spinal implants marks a watershed in the evolution of metastatic spine tumour surgery (MSTS), which has evolved from standalone decompressive laminectomy to instrumented stabilization and decompression with reconstruction when necessary. Fusion may not be feasible after MSTS due to poor quality of graft host bed along with adjunct chemotherapy and/or radiotherapy postoperatively. With an increase in the survival of patients with spinal tumours, there is a probability of an increase in the rate of implant failure. This review aims to help establish a clear understanding of implants/constructs used in MSTS and to highlight the fundamental biomechanics of implant/construct failures.

METHODS

Published literature on implant failure after spine surgery and MSTS has been reviewed. The evolution of spinal implants and their role in MSTS has been briefly described. The review defines implant/construct failures using radiological parameters that are practical, feasible, and derived from historical descriptions. We have discussed common modes of implant/construct failure after MSTS to allow further understanding, interception, and prevention of catastrophic failure.

RESULTS

Implant failure rates in MSTS are in the range of 2-8%. Variability in patterns of failure has been observed based on anatomical region and the type of constructs used. Patients with construct/implant failures may or may not be symptomatic and present either as early (< 3months) or late failures (> 3months). It has been noted that not all the implant failures after MSTS result in revisions.

CONCLUSION

Based on the observed radiological criteria and clinical presentations, we have proposed a clinico-radiological classification for implant/construct failure after MSTS.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/157491
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
benneker2.pdftextAdobe PDF1.46 MBpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: d1c7f7 [27.06. 13:56]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo