  3. Imaging algorithms and CT protocols in trauma patients: survey of Swiss emergency centers.
 

Imaging algorithms and CT protocols in trauma patients: survey of Swiss emergency centers.

Options
  • Details
BORIS DOI
10.7892/boris.101439
Date of Publication
May 2017
Publication Type
Article
Division/Institute

Universitätsinstitut ...

Contributor
Hinzpeter, R
Boehm, T
Boll, D
Constantin, C
Del Grande, F
Fretz, V
Leschka, S
Ohletz, T
Brönnimann, Michael
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Schmidt, S
Treumann, T
Poletti, P-A
Alkadhi, Hatem
Subject(s)

600 - Technology::610...

Series
European radiology
ISSN or ISBN (if monograph)
0938-7994
Publisher
Springer
Language
English
Publisher DOI
10.1007/s00330-016-4574-1
PubMed ID
27595837
Uncontrolled Keywords

Algorithm Computed to...

Description
OBJECTIVES

To identify imaging algorithms and indications, CT protocols, and radiation doses in polytrauma patients in Swiss trauma centres.

METHODS

An online survey with multiple choice questions and free-text responses was sent to authorized level-I trauma centres in Switzerland.

RESULTS

All centres responded and indicated that they have internal standardized imaging algorithms for polytrauma patients. Nine of 12 centres (75 %) perform whole-body CT (WBCT) after focused assessment with sonography for trauma (FAST) and conventional radiography; 3/12 (25 %) use WBCT for initial imaging. Indications for WBCT were similar across centres being based on trauma mechanisms, vital signs, and presence of multiple injuries. Seven of 12 centres (58 %) perform an arterial and venous phase of the abdomen in split-bolus technique. Six of 12 centres (50 %) use multiphase protocols of the head (n = 3) and abdomen (n = 4), whereas 6/12 (50 %) use single-phase protocols for WBCT. Arm position was on the patient`s body during scanning (3/12, 25 %), alongside the body (2/12, 17 %), above the head (2/12, 17 %), or was changed during scanning (5/12, 42 %). Radiation doses showed large variations across centres ranging from 1268-3988 mGy*cm (DLP) per WBCT.

CONCLUSIONS

Imaging algorithms in polytrauma patients are standardized within, but vary across Swiss trauma centres, similar to the individual WBCT protocols, resulting in large variations in associated radiation doses.

KEY POINTS

• Swiss trauma centres have internal standardized imaging algorithms for trauma patients • Whole-body CT is most commonly used for imaging of trauma patients • CT protocols and radiation doses vary greatly across Swiss trauma centres.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/153362
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
10.1007_s00330-016-4574-1.pdftextAdobe PDF511.41 KBpublisherpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 27ad28 [15.10. 15:21]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo