Publication:
μCT-based trabecular anisotropy can be reproducibly computed from HR-pQCT scans using the triangulated bone surface

cris.virtual.author-orcid0000-0002-4712-7047
cris.virtualsource.author-orcidde5fe57c-4155-4483-859e-7772b99fd63d
cris.virtualsource.author-orcid09c1f812-a6cc-44d4-8cd8-fc5edb32adf2
cris.virtualsource.author-orcid8e8a2467-96b0-4987-8997-57604a4b0630
datacite.rightsopen.access
dc.contributor.authorSeyed Hosseini, Hadi
dc.contributor.authorMaquer, Ghislain Bernard
dc.contributor.authorZysset, Philippe
dc.date.accessioned2024-10-25T05:13:56Z
dc.date.available2024-10-25T05:13:56Z
dc.date.issued2017-01-17
dc.description.abstractThe trabecular structure can be assessed at the wrist or tibia via high-resolution peripheral quantitative computed tomography (HR-pQCT). Yet on this modality, the performance of the existing methods, evaluating trabecular anisotropy is usually overlooked, especially in terms of reproducibility. We thus proposed to compare the TRI routine used by SCANCO Medical AG (Brüttisellen, Switzerland), the classical mean intercept length (MIL), and the grey-level structure tensor (GST) to the mean surface length (MSL), a new method for evaluating a second-order fabric tensor based on the triangulation of the bone surface. The distal radius of 24 fresh-frozen human forearms was scanned three times via HR-pQCT protocols (61 μm, 82 μm nominal voxel size), dissected, and imaged via micro computed tomography (μCT) at 16 μm nominal voxel size. After registering the scans, we compared for each resolution the fabric tensors, determined by the mentioned techniques for 182 trabecular regions of interest. We then evaluated the reproducibility of the fabric information measured by HR-pQCT via precision errors. On μCT, TRI and GST were respectively the best and worst surrogates for MILμCT (MIL computed on μCT) in terms of eigenvalues and main direction of anisotropy. On HR-pQCT, however, MSL provided the best approximation of MILμCT. Surprisingly, surface-based approaches (TRI, MSL) also proved to be more precise than both MIL and GST. Our findings confirm that MSL can reproducibly estimate MILμCT, the current gold standard. MSL thus enables the direct mapping of the fabric-dependent material properties required in homogenised HR-pQCT-based finite element models.
dc.description.numberOfPages7
dc.description.sponsorshipInstitut für chirurgische Technologien und Biomechanik (ISTB)
dc.identifier.doi10.7892/boris.96021
dc.identifier.pmid28109918
dc.identifier.publisherDOI10.1016/j.bone.2017.01.016
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/150156
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofBone
dc.relation.issn8756-3282
dc.relation.organizationDCD5A442BCD5E17DE0405C82790C4DE2
dc.relation.urlhttps://www.researchgate.net/publication/312544117_mCT-based_trabecular_anisotropy_can_be_reproducibly_computed_from_HR-pQCT_scans_using_the_triangulated_bone_surface
dc.subject.ddc500 - Science::570 - Life sciences; biology
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleμCT-based trabecular anisotropy can be reproducibly computed from HR-pQCT scans using the triangulated bone surface
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
dspace.file.typetext
oaire.citation.endPage120
oaire.citation.startPage114
oaire.citation.volume97
oairecerif.author.affiliationInstitut für chirurgische Technologien und Biomechanik (ISTB)
oairecerif.author.affiliationInstitut für chirurgische Technologien und Biomechanik (ISTB)
oairecerif.author.affiliationInstitut für chirurgische Technologien und Biomechanik (ISTB)
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.embargoChanged2018-05-01 00:30:04
unibe.description.ispublishedpub
unibe.eprints.legacyId96021
unibe.journal.abbrevTitleBONE
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 2 of 2
Name:
Hosseini2017.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published
Name:
Hosseini2017-Accepted_Manuscript.pdf
Size:
1.06 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by-nc-nd/4.0
Content:
accepted

Collections