  2. Publications
  3. μCT-based trabecular anisotropy can be reproducibly computed from HR-pQCT scans using the triangulated bone surface
 

μCT-based trabecular anisotropy can be reproducibly computed from HR-pQCT scans using the triangulated bone surface

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.96021
Publisher DOI
10.1016/j.bone.2017.01.016
PubMed ID
28109918
Description
The trabecular structure can be assessed at the wrist or tibia via high-resolution peripheral quantitative computed tomography (HR-pQCT). Yet on this modality, the performance of the existing methods, evaluating trabecular anisotropy is usually overlooked, especially in terms of reproducibility. We thus proposed to compare the TRI routine used by SCANCO Medical AG (Brüttisellen, Switzerland), the classical mean intercept length (MIL), and the grey-level structure tensor (GST) to the mean surface length (MSL), a new method for evaluating a second-order fabric tensor based on the triangulation of the bone surface. The distal radius of 24 fresh-frozen human forearms was scanned three times via HR-pQCT protocols (61 μm, 82 μm nominal voxel size), dissected, and imaged via micro computed tomography (μCT) at 16 μm nominal voxel size. After registering the scans, we compared for each resolution the fabric tensors, determined by the mentioned techniques for 182 trabecular regions of interest. We then evaluated the reproducibility of the fabric information measured by HR-pQCT via precision errors. On μCT, TRI and GST were respectively the best and worst surrogates for MILμCT (MIL computed on μCT) in terms of eigenvalues and main direction of anisotropy. On HR-pQCT, however, MSL provided the best approximation of MILμCT. Surprisingly, surface-based approaches (TRI, MSL) also proved to be more precise than both MIL and GST. Our findings confirm that MSL can reproducibly estimate MILμCT, the current gold standard. MSL thus enables the direct mapping of the fabric-dependent material properties required in homogenised HR-pQCT-based finite element models.
Date of Publication
2017-01-17
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Seyed Hosseini, Hadi
Institut für chirurgische Technologien und Biomechanik (ISTB)
Maquer, Ghislain Bernard
Institut für chirurgische Technologien und Biomechanik (ISTB)
Zysset, Philippeorcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)
Series
Bone
Publisher
Elsevier
ISSN
8756-3282
Related URL(s)
https://www.researchgate.net/publication/312544117_mCT-based_trabecular_anisotropy_can_be_reproducibly_computed_from_HR-pQCT_scans_using_the_triangulated_bone_surface
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo