dc.description.abstractThe latest generation of leadless pacemakers is able to provide atrio-ventricular synchrony (AVS). The performance of these devices regarding ambulant AVS is still under debate. In an analysis by Garweg and co-authors, the AM-VP device counter was considered a reliable marker for true AVS and outpatient AVS in a large cohort was estimated to be ~75%. This editorial critically reflects the findings of Garweg et al. In general, evidence is increasing that leadless pacemakers with mechanical sensing provide an adequate degree of AVS in the outpatient setting. Device counters may indeed help to better understand specific programming-related challenges, but important questions regarding their diagnostic accuracy remain. This article is protected by copyright. All rights reserved.
dc.description.numberOfPages2
dc.description.sponsorshipUniversitätsklinik für Kardiologie
dc.identifier.doi10.48350/174414
dc.identifier.pmid36317456
dc.identifier.publisherDOI10.1111/jce.15723
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/88598
dc.language.isoen
dc.publisherWiley-Blackwell
dc.relation.ispartofJournal of cardiovascular electrophysiology
dc.relation.issn1045-3873
dc.relation.organizationD7AF601F59994366806EA9DF347DE794
dc.relation.organizationDCD5A442BB15E17DE0405C82790C4DE2
dc.relation.organizationDE7C6E88B44384ADE0405C82960C5EAC
dc.subjectAV synchrony Micra atrio-ventricular synchrony leadless leadless pacemakers
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleReal-life ambulatory performance of leadless AV synchronous pacemakers - are all questions answered?
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage208
oaire.citation.issue1
oaire.citation.startPage207
oaire.citation.volume34
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliation2ARTORG Center - Biomechanics
unibe.contributor.rolecreator
unibe.date.embargoChanged2023-11-01 23:25:06
unibe.date.licenseChanged2022-11-03 13:08:49
unibe.description.ispublishedpub
unibe.eprints.legacyId174414
unibe.journal.abbrevTitleJ CARDIOVASC ELECTR
unibe.refereedtrue
unibe.subtype.articlecontribution

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Cardiovasc_electrophysiol_-_2022_-_Haeberlin_-_Real_life_ambulatory_performance_of_leadless_AV_synchronous_pacemakers_are.pdf
Size:
263.27 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
accepted

Collections