• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Real-life ambulatory performance of leadless AV synchronous pacemakers - are all questions answered?
 

Real-life ambulatory performance of leadless AV synchronous pacemakers - are all questions answered?

Options
  • Details
BORIS DOI
10.48350/174414
Date of Publication
January 2023
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Contributor
Häberlin, Andreas David Heinrichorcid-logo
Universitätsklinik für Kardiologie
ARTORG Center - Biomechanics
Subject(s)

600 - Technology::610...

Series
Journal of cardiovascular electrophysiology
ISSN or ISBN (if monograph)
1045-3873
Publisher
Wiley-Blackwell
Language
English
Publisher DOI
10.1111/jce.15723
PubMed ID
36317456
Uncontrolled Keywords

AV synchrony Micra at...

Description
The latest generation of leadless pacemakers is able to provide atrio-ventricular synchrony (AVS). The performance of these devices regarding ambulant AVS is still under debate. In an analysis by Garweg and co-authors, the AM-VP device counter was considered a reliable marker for true AVS and outpatient AVS in a large cohort was estimated to be ~75%. This editorial critically reflects the findings of Garweg et al. In general, evidence is increasing that leadless pacemakers with mechanical sensing provide an adequate degree of AVS in the outpatient setting. Device counters may indeed help to better understand specific programming-related challenges, but important questions regarding their diagnostic accuracy remain. This article is protected by copyright. All rights reserved.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/88598
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Cardiovasc_electrophysiol_-_2022_-_Haeberlin_-_Real_life_ambulatory_performance_of_leadless_AV_synchronous_pacemakers_are.pdftextAdobe PDF263.27 KBpublisheracceptedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 960e9e [21.08. 13:49]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo