• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Craniospinal irradiation using pencil beam Scanning: The PSI experience.

Craniospinal irradiation using pencil beam Scanning: The PSI experience.

Details
Files
DOI
10.48620/76264
Publisher DOI
10.1016/j.ejmp.2024.104817
PubMed ID
39393158
Abstract
Introduction
We present the dosimetric evaluation of craniospinal irradiation (CSI) treatments delivered with protons at Paul Scherrer Institute (PSI), with special focus on local recurrences and late toxicity outcome.
Methods
This study included 71 children, adolescents and young adults (c-AYA), who received or intended to receive (3 patients, pts) CSI using PBS-PT at PSI between 2004 and January 2021. The most frequent primary tumours were: medulloblastoma (42 pts), ependymoma (8 pts) and germ cell tumors (6 pts). The patients were treated prone on Gantry1 (G1; 22 pts) up to 2017, and afterwards supine on Gantry2 (G2; 49 pts). Accuracy of prone vs. supine setup was evaluated. Nine patients received CSI for local failure (LF) after a first course of local fractionated radiation therapy (RT). For 59/71 patients (excluding three patients not receiving PBS-PT CSI and nine preirradiated) CSI plans were compared considering gantry and planning technique. Detailed analysis of the full treatment (CSI and boost series) was performed for 8 patients presenting with LFs (4 of them presented also distal failure) and for selected patients presenting with late toxicity (G2 to G4) or asymptomatic radiation-induced radiological findings.
Results
Supine positioning resulted in lower systematic and random errors as compared to prone (0.25 mm and 0.4 mm systematic errors respectively for supine and prone; random errors in PA direction reduced from 1.8 mm for prone to 1.4 mm for supine).
Conclusions
LFs were not correlated with potential dose inaccuracies or lack of robustness and no correlation of toxicities to enhanced LET have been observed.
Date Issued
2024-11
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Children
•
Cranial spinal irradiation
•
Patient-related outcomes
•
Proton treatment
•
Toxicity
•
dose-average LET
Language(s)
en
Author(s)
Bolsi, Alessandra
De Angelis, Claudio
Vázquez, Miriam  
Siewert, Dorota
Correia, Dora  
Bachmann, Nicolas  
Clinic of Radiation Oncology  
Lomax, Antony J
Pica, Alessia  
Weber, Damien C  
Clinic of Radiation Oncology  
Additional Credits
Clinic of Radiation Oncology  
Journal
Physica Medica
Publisher
Elsevier
ISSN
1120-1797
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify