  3. Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy.
 

Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy.

Options
  • Details
BORIS DOI
10.7892/boris.147331
Date of Publication
May 2020
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Contributor
Schmitt, Daniela
Blanck, Oliver
Gauer, Tobias
Fix, Michaelorcid-logo
Universitätsklinik für Radio-Onkologie, Medizinische Strahlenphysik
Brunner, Thomas B
Fleckenstein, Jens
Loutfi-Krauss, Britta
Manser, Peter
Universitätsklinik für Radio-Onkologie, Medizinische Strahlenphysik
Werner, Rene
Wilhelm, Maria-Lisa
Baus, Wolfgang W
Moustakis, Christos
Series
Strahlentherapie und Onkologie
ISSN or ISBN (if monograph)
1439-099X
Publisher
Springer
Language
English
Publisher DOI
10.1007/s00066-020-01583-2
PubMed ID
32211939
Uncontrolled Keywords

FSRT Radiosurgery Rec...

Description
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/55483
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Schmitt2020_Article_TechnologicalQualityRequiremen (1).pdftextAdobe PDF573.93 KBpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 27ad28 [15.10. 15:21]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo