Publication:
Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy.

cris.virtual.author-orcid0000-0002-3911-3403
cris.virtualsource.author-orcidfb089609-c18a-4ab4-bf39-a2d95248a9a9
cris.virtualsource.author-orcidc171715f-9c9f-4166-9093-7f89b4d6ffe9
datacite.rightsopen.access
dc.contributor.authorSchmitt, Daniela
dc.contributor.authorBlanck, Oliver
dc.contributor.authorGauer, Tobias
dc.contributor.authorFix, Michael
dc.contributor.authorBrunner, Thomas B
dc.contributor.authorFleckenstein, Jens
dc.contributor.authorLoutfi-Krauss, Britta
dc.contributor.authorManser, Peter
dc.contributor.authorWerner, Rene
dc.contributor.authorWilhelm, Maria-Lisa
dc.contributor.authorBaus, Wolfgang W
dc.contributor.authorMoustakis, Christos
dc.date.accessioned2024-10-05T11:52:48Z
dc.date.available2024-10-05T11:52:48Z
dc.date.issued2020-05
dc.description.abstractThis review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
dc.description.numberOfPages23
dc.description.sponsorshipUniversitätsklinik für Radio-Onkologie, Medizinische Strahlenphysik
dc.identifier.doi10.7892/boris.147331
dc.identifier.pmid32211939
dc.identifier.publisherDOI10.1007/s00066-020-01583-2
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/55483
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofStrahlentherapie und Onkologie
dc.relation.issn1439-099X
dc.relation.organizationClinic of Radiation Oncology, Medical Radiation Physics
dc.subjectFSRT Radiosurgery Recommendations SBRT SRS Technique
dc.titleTechnological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage443
oaire.citation.issue5
oaire.citation.startPage421
oaire.citation.volume196
oairecerif.author.affiliationUniversitätsklinik für Radio-Onkologie, Medizinische Strahlenphysik
oairecerif.author.affiliationUniversitätsklinik für Radio-Onkologie, Medizinische Strahlenphysik
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2020-11-05 15:43:31
unibe.description.ispublishedpub
unibe.eprints.legacyId147331
unibe.refereedtrue
unibe.subtype.articlereview

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Schmitt2020_Article_TechnologicalQualityRequiremen (1).pdf
Size:
573.93 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections