• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Research Data
  • Organizations
  • Researchers
  • More
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Heart rate variability does not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesia
 

Heart rate variability does not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesia

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.24567
Publisher DOI
10.1093/bja/aem085
PubMed ID
17468493
Description
BACKGROUND: Hypnotic depth but not haemodynamic responsiveness is measured with EEG-based monitors. In this study we compared heart rate variability (HRV) in unstimulated patients and stimulation-induced HRV at different levels of anaesthesia. METHODS: A total of 95 ASA I or II patients were randomly assigned to five groups (Group 1: BIS 45(5), remifentanil 1 ng ml(-1); Group 2: BIS 45(5), remifentanil 2 ng ml(-1); Group 3: BIS 45(5), remifentanil 4 ng ml(-1); Group 4: BIS 30(5), remifentanil 2 ng ml(-1); Group 5: BIS 60(5), remifentanil 2 ng ml(-1)). A time- and frequency-domain analysis of the RR interval (RRI) from the electrocardiogram was performed. HRV before induction, before and after a 5 s tetanic stimulus of the ulnar nerve, and before and after tracheal intubation was compared between groups, between stimuli, and between responders to intubation [systolic arterial pressure (SAP) increase >20 mm Hg, a maximal heart rate (HR) after intubation >90 min(-1) or both] and non-responders (anova). RESULTS: Induction of anaesthesia significantly lowered HR and HRV. Mean RRI before stimulation was higher in G3 than in G1, G2, and G4 (P < 0.001), whereas the other HRV parameters were similar. Intubation induced a greater HRV response than tetanic stimulation. The mean RRI after intubation was lower in G3 compared with the other groups and the sd of the RRI after tetanic stimulation was lower in G3 compared with G5. Otherwise, unstimulated HRV and stimulation-induced HRV were similar in responders and non-responders. CONCLUSION: HRV parameters discriminate between awake and general anaesthesia, are different after tracheal intubation and a 5 s ulnar nerve stimulation, but do not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesia.
Date of Publication
2007
Publication Type
article
Language(s)
en
Contributor(s)
Luginbühl, Martin
Universitätsklinik für Anästhesiologie und Schmerztherapie
Yppärilä-Wolters, H
Rüfenacht, M
Petersen-Felix, S
Korhonen, I
Additional Credits
Universitätsklinik für Anästhesiologie und Schmerztherapie
Series
British journal of anaesthesia
Publisher
Oxford University Press
ISSN
0007-0912
ISBN
17468493
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 4f1f0f [ 1.12. 12:07]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo