  3. Finite element analysis of stress distribution in autotransplanted molars.
 

Finite element analysis of stress distribution in autotransplanted molars.

Options
  • Details
  • Files
BORIS DOI
10.48350/166602
Publisher DOI
10.1016/j.jdent.2022.104082
PubMed ID
35247471
Description
OBJECTIVE

The biomechanical response of an autotransplanted tooth and surrounding bone to occlusal loads is not well-known. The aim of the present study was to investigate the effect of root form and occlusal morphology on stress distribution in autotransplanted teeth and surrounding bone by using finite element analysis (FEA).

METHODS

Seven FEA models representing different autotransplanted tooth situations were generated: (a) first molar, (b) third molar, (c) root canal-treated third molar, (d) root canal-treated, ankylosed, third molar, (e) crowned third molar, (f) crowned and root canal-treated third molar, (g) root canal-treated, ankylosed, and crowned third molar. Load (200 N) was applied on the occlusal surface, parallel to the long axis of the tooth. Maximum von Mises stress values on dentin and surrounding bone were calculated for each situation.

RESULTS

Differences in stress distribution were observed among models. In ankylosed model, stress was primarily observed at the coronal region of the tooth. The stress was observed more at the coronal region of the tooth in crowned models compared with the non-crowned models. The stress distribution was homogeneous with root canal-treated and crowned autotransplanted tooth.

CONCLUSIONS

The occlusal morphology and root form of the autotransplanted tooth affected the stress in surrounding bone at the transfer site and the biomechanical response of the tooth. The stress was more homogeneous in crowned tooth and primarily observed at the coronal region, which may decrease the risk for root resorption.

CLINICAL SIGNIFICANCE

Root configuration, occlusal form and root canal treatment induce significant changes on the stress distribution on teeth and bone, including characteristic stress concentration and increased stress values. Clinicians can consider crowning autotransplanted teeth for improved stress distribution within the tooth structure.
Date of Publication
2022-04
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
Autotransplantation ankylosis biomimetic finite elemental analysis periodontal ligament
Language(s)
en
Contributor(s)
Kırmalı, Ömer
Türker, Nurullah
Akar, Türker
Yilmaz, Burak
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Additional Credits
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Series
Journal of dentistry
Publisher
Elsevier Science
ISSN
0300-5712
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 7bc660 [30.01. 11:07]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo