  2. Publications
  3. Quality Control of Serum and Plasma by Quantification of (4E,14Z)-Sphingadienine-C18-1-Phosphate Uncovers Common Preanalytical Errors During Handling of Whole Blood
 

Quality Control of Serum and Plasma by Quantification of (4E,14Z)-Sphingadienine-C18-1-Phosphate Uncovers Common Preanalytical Errors During Handling of Whole Blood

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.125820
Publisher DOI
10.1373/clinchem.2017.277905
PubMed ID
29567661
Description
BACKGROUND:
Nonadherence to standard operating procedures (SOPs) during handling and processing of whole blood is one of the most frequent causes affecting the quality of serum and plasma. Yet, the quality of blood samples is of the utmost importance for reliable, conclusive research findings, valid diagnostics, and appropriate therapeutic decisions.

METHODS:
UHPLC-MS-driven nontargeted metabolomics was applied to identify biomarkers that reflected time to processing of blood samples, and a targeted UHPLC-MS analysis was used to quantify and validate these biomarkers.

RESULTS:
We found that (4E,14Z)-sphingadienine-C18-1-phosphate (S1P-d18:2) was suitable for the reliable assessment of the pronounced changes in the quality of serum and plasma caused by errors in the phase between collection and centrifugation of whole blood samples. We rigorously validated S1P-d18:2, which included the use of practicality tests on >1400 randomly selected serum and plasma samples that were originally collected during single- and multicenter trials and then stored in 11 biobanks in 3 countries. Neither life-threatening disease states nor strenuous metabolic challenges (i.e., high-intensity exercise) affected the concentration of S1P-d18:2. Cutoff values for sample assessment were defined (plasma, ≤0.085 μg/mL; serum, ≤0.154 μg/mL).

CONCLUSIONS:
Unbiased valid monitoring to check for adherence to SOP-dictated time for processing to plasma or serum and/or time to storage of whole blood at 4 °C is now feasible. This novel quality assessment step could enable scientists to uncover common preanalytical errors, allowing for identification of serum and plasma samples that should be excluded from certain investigations. It should also allow control of samples before long-term storage in biobanks.
Date of Publication
2018
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Language(s)
en
Contributor(s)
Liu, Xinyu
Hoene, Miriam
Yin, Peiyuan
Fritsche, Louise
Plomgaard, Peter
Hansen, Jakob S.
Nakas, Christos T.
Universitätsinstitut für Klinische Chemie (UKC)
Niess, Andreas M.
Hudemann, Jens
Haap, Michael
Mendy, Maimuna
Weigert, Cora
Wang, Xiaolin
Fritsche, Andreas
Peter, Andreas
Häring, Hans-Ulrich
Xu, Guowang
Lehmann, Rainer
Additional Credits
Universitätsinstitut für Klinische Chemie (UKC)
Series
Clinical chemistry
Publisher
American Association for Clinical Chemistry
ISSN
0009-9147
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 9f4e9a [ 5.02. 18:48]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo