  3. Quantification of thermal dose in moderate clinical hyperthermia with radiotherapy: a relook using temperature-time area under the curve (AUC).
 

Quantification of thermal dose in moderate clinical hyperthermia with radiotherapy: a relook using temperature-time area under the curve (AUC).

Options
  • Details
  • Files
BORIS DOI
10.48350/154571
Publisher DOI
10.1080/02656736.2021.1875060
PubMed ID
33627018
Description
BACKGROUND

Thermal dose in clinical hyperthermia reported as cumulative equivalent minutes (CEM) at 43 °C (CEM43) and its variants are based on direct thermal cytotoxicity assuming Arrhenius 'break' at 43 °C. An alternative method centered on the actual time-temperature plot during each hyperthermia session and its prognostic feasibility is explored.

METHODS AND MATERIALS

Patients with bladder cancer treated with weekly deep hyperthermia followed by radiotherapy were evaluated. From intravesical temperature (T) recordings obtained every 10 secs, the area under the curve (AUC) was computed for each session for T > 37 °C (AUC > 37 °C) and T ≥ 39 °C (AUC ≥ 39 °C). These along with CEM43, CEM43(>37 °C), CEM43(≥39 °C), Tmean, Tmin and Tmax were evaluated for bladder tumor control.

RESULTS

Seventy-four hyperthermia sessions were delivered in 18 patients (median: 4 sessions/patient). Two patients failed in the bladder. For both individual and summated hyperthermia sessions, the Tmean, CEM43, CEM43(>37 °C), CEM43(≥39 °C), AUC > 37 °C and AUC ≥ 39 °C were significantly lower in patients who had a local relapse. Individual AUC ≥ 39 °C for patients with/without local bladder failure were 105.9 ± 58.3 °C-min and 177.9 ± 58.0 °C-min, respectively (p = 0.01). Corresponding summated AUC ≥ 39 °C were 423.7 ± 27.8 °C-min vs. 734.1 ± 194.6 °C-min (p < 0.001), respectively. The median AUC ≥ 39 °C for each hyperthermia session in patients with bladder tumor control was 190 °C-min.

CONCLUSION

AUC ≥ 39 °C for each hyperthermia session represents the cumulative time-temperature distribution at clinically defined moderate hyperthermia in the range of 39 °C to 45 °C. It is a simple, mathematically computable parameter without any prior assumptions and appears to predict treatment outcome as evident from this study. However, its predictive ability as a thermal dose parameter merits further evaluation in a larger patient cohort.
Date of Publication
2021
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
AUC CEM Thermal dose area under the curve hyperthermia thermometry
Language(s)
en
Contributor(s)
Datta, Niloy R
Marder, Dietmar
Datta, Sneha
Meister, Andreas
Puric, Emsad
Stutz, Emanuel
Universitätsklinik für Radio-Onkologie
Rogers, Susanne
Eberle, Brigitte
Timm, Olaf
Staruch, Michal
Riesterer, Oliver
Bodis, Stephan
Additional Credits
Universitätsklinik für Radio-Onkologie
Series
International journal of hyperthermia
Publisher
Taylor & Francis
ISSN
1464-5157
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 9f4e9a [ 5.02. 18:48]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo