  3. Five-year outcomes with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with acute coronary syndrome: A subgroup analysis of the BIOSCIENCE trial.
 

Five-year outcomes with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with acute coronary syndrome: A subgroup analysis of the BIOSCIENCE trial.

Options
  • Details
  • Files
BORIS DOI
10.48350/153392
Publisher DOI
10.1016/j.carrev.2021.02.008
PubMed ID
33653633
Description
BACKGROUND

Thin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) have been shown to reduce target lesion failure (TLF) at one-year follow-up compared with durable polymer everolimus-eluting stents (DP-EES) among patients with acute coronary syndrome (ACS). The long-term clinical benefits of thin-strut BP-SES over DP-EES in ACS patients after complete degradation of the polymer coating remain uncertain.

METHODS

We performed a post-hoc subgroup analysis of ACS patients included into the BIOSCIENCE randomized trial (NCT01443104). The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction or clinically indicated target lesion revascularization, at 5 years.

RESULTS

Among 2119 patients enrolled between March 2012 and May 2013, 1131 (53%) presented with ACS. The 5-year cumulative incidence of TLF was significantly lower in patients with ACS compared to chronic coronary syndrome [16.5% vs. 22.9%; rate ratio (RR), 0.69; 95% confidence interval (CI), 0.57-0.85; p < 0.001]. At 5 years, TLF occurred similarly in ACS patients treated with BP-SES and DP-EES (16.9% vs. 16.0%; RR, 1.04; 95% CI, 0.78-1.41; p = 0.78). The individual components of the primary endpoint did not differ between ACS patients treated with BP-SES or DP-EES at 5 years. Overall, there was no interaction between clinical presentation and treatment effect.

CONCLUSIONS

In a subgroup analysis of the BIOSCIENCE trial, we found no difference in long-term outcomes between ACS patients treated with BP-SES or DP-EES at 5 years.
Date of Publication
2022-01
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
Acute coronary syndrome Biodegradable polymer Clinical outcomes Drug-eluting stent
Language(s)
en
Contributor(s)
Iglesias, Juan F
Heg, Dierik Hansorcid-logo
Clinical Trials Unit Bern (CTU)
Roffi, Marco
Degrauwe, Sophie
Tüller, David
Muller, Olivier
Brinkert, Miriam
Cook, Stéphane
Weilenmann, Daniel
Kaiser, Christoph
Cuculi, Florim
Valgimigli, Marco
Universitätsklinik für Kardiologie
Jüni, Peter
Windecker, Stephan
Universitätsklinik für Kardiologie
Pilgrim, Thomas
Universitätsklinik für Kardiologie
Additional Credits
Clinical Trials Unit Bern (CTU)
Universitätsklinik für Kardiologie
Series
Cardiovascular revascularization medicine
Publisher
Elsevier
ISSN
1553-8389
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: ae9592 [15.12. 16:43]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo