• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Research Data
  • Organizations
  • Researchers
  • Statistics
  • More
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. COVID-19 patients often show high-titer non-platelet-activating anti-PF4/heparin IgG antibodies.
 

COVID-19 patients often show high-titer non-platelet-activating anti-PF4/heparin IgG antibodies.

Options
  • Details
  • Files
BORIS DOI
10.48350/152391
Publisher DOI
10.1111/jth.15262
PubMed ID
33550713
Description
BACKGROUND

Heparin-induced thrombocytopenia (HIT) is a severe adverse reaction to heparin caused by heparin-dependent, platelet activating anti-platelet factor 4 (PF4)/heparin antibodies. Heparin is a cornerstone of treatment in critically ill COVID-19 patients. HIT antibodies can be detected by antigen tests and functional tests. Often strong reactivity in the antigen test is used as surrogate marker for the presence of clinically relevant, platelet activating antibodies. We observed an unexpectedly high percentage of COVID-19 patients, clinically suspected to have HIT, with high titer anti-PF4/heparin antibodies, but a negative functional test.

OBJECTIVE

We investigated whether in COVID-19 patients a serum-derived factor inhibits the heparin-induced platelet activation test (HIPA).

METHODS AND RESULTS

12 COVID-19 patients with suspected HIT were tested. Three samples tested negative in all assays; nine samples tested positive by antigen tests, among which only three tested also positive by HIPA. When we spiked COVID-19 serum or control serum with the human HIT antibody like mAb 5B9, reactivity of 5B9 remained the same. Also the purified IgG fractions of COVID-19 sera testing strongly positive in the PF4/heparin antigen test but negative in the functional test did not show increased reactivity in the functional test in comparison to the original serum. Both results make a functionally inhibitory factor in the serum/plasma of COVID-19 patients highly unlikely.

CONCLUSION

COVID-19 patients often present with strong reactivity in PF4/heparin antigen tests without the presence of platelet-activating antibodies. Diagnosis of HIT requires confirmation of heparin-dependent, platelets activating antibodies to avoid overdiagnosis and overtreatment with non-heparin anticoagulants.
Date of Publication
2021-05
Publication Type
article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
COVID-19 Heparin Platelet Factor 4 Thrombocytopenia Thrombosis
Language(s)
en
Contributor(s)
Brodard, Justine
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Kremer Hovinga Strebel, Johanna Annaorcid-logo
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Fontana, Pierre
Studt, Jan-Dirk
Gruel, Yves
Greinacher, Andreas
Additional Credits
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Series
Journal of thrombosis and haemostasis
Publisher
Wiley-Blackwell
ISSN
1538-7836
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 4f1f0f [ 1.12. 12:07]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo