  3. The IN.PACT DEEP Clinical Drug-Coated Balloon Trial: 5-Year Outcomes.
 

The IN.PACT DEEP Clinical Drug-Coated Balloon Trial: 5-Year Outcomes.

Options
  • Details
BORIS DOI
10.7892/boris.142174
Date of Publication
February 24, 2020
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Contributor
Zeller, Thomas
Micari, Antonio
Scheinert, Dierk
Baumgartner, Iris
Universitätsklinik für Angiologie
Bosiers, Marc
Vermassen, Frank E G
Banyai, Martin
Shishehbor, Mehdi H
Wang, Hong
Brodmann, Marianne
Subject(s)

600 - Technology::610...

Series
JACC. Cardiovascular Interventions
ISSN or ISBN (if monograph)
1876-7605
Publisher
Elsevier
Language
English
Publisher DOI
10.1016/j.jcin.2019.10.059
PubMed ID
32081236
Uncontrolled Keywords

CD-TLR IN.PACT DEEP a...

Description
OBJECTIVES

The goal of this study was to evaluate the 5-year follow-up data of the IN.PACT DEEP (Randomized IN.PACT Amphirion Drug-Coated Balloon [DCB] vs. Standard Percutaneous Transluminal Angioplasty [PTA] for the Treatment of Below-the-Knee Critical Limb Ischemia [CLI]) trial.

BACKGROUND

Initial studies from randomized controlled trials have shown comparable short-term outcomes of DCB angioplasty versus PTA in patients with CLI with infrapopliteal disease. However, the long-term safety and effectiveness of DCB angioplasty remain unknown in this patient population.

METHODS

IN.PACT DEEP was an independently adjudicated prospective, multicenter, randomized controlled trial that enrolled 358 subjects with CLI. Subjects were randomized 2:1 to DCB angioplasty or PTA. Assessments through 5 years included freedom from clinically driven target lesion revascularization, amputation, and all-cause death. Additional assessments were conducted to identify risk factors for death and major amputation, including paclitaxel dose tercile.

RESULTS

Freedom from clinically driven target lesion revascularization through 5 years was 70.9% and 76.0% (log-rank p = 0.406), and the incidence of the safety composite endpoint was 59.8% and 57.5% (log-rank p = 0.309) in the DCB angioplasty and PTA groups, respectively. The rate of major amputation was 15.4% for DCB angioplasty compared with 10.6% for PTA (log-rank p = 0.108). Given the recent concern regarding a late mortality signal in patients treated with paclitaxel-coated devices, additional analyses from this study showed no increase in all-cause mortality with DCB angioplasty (39.4%) compared with PTA (44.9%) (log-rank p = 0.727). Predictors of mortality included age, Rutherford category >4, and previous revascularization but not paclitaxel by dose tercile.

CONCLUSIONS

Tibial artery revascularization in patients with CLI using DCB angioplasty resulted in comparable long-term safety and effectiveness as PTA. Paclitaxel exposure was not related to increased risk for amputation or all-cause mortality at 5-year follow-up. (Study of IN.PACT Amphirion™ Drug Eluting Balloon vs. Standard PTA for the Treatment of Below the Knee Critical Limb Ischemia [INPACT-DEEP]; NCT00941733).
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/35047
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
ZellerT_TheIN.PACTDeepClinicalDrug-CoatedBallonTrial_JAmCollCardiolIntv_2020.pdfAdobe PDF1.31 MBpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 27ad28 [15.10. 15:21]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo