Description
BACKGROUND

Acromioclavicular joint (ACJ) injuries are common. Despite this, it remains unclear how best to assess, classify, and manage these cases. A simple, reliable, valid, and accurate radiographic parameter to measure ACJ displacement would allow improved consistency of diagnosis and subsequent treatment pathways.

PURPOSE

To evaluate "the circles measurement" and associated "ABC classification" as a tool for assessing ACJ displacement and injury classification.

STUDY DESIGN

Descriptive laboratory study.

METHODS

The circles measurement is taken from a lateral Alexander radiograph of the shoulder. The measurement is the center-to-center distance between 2 circles drawn to define the lateral extent of the clavicle and the anteromedial extent of the acromion; it is independent of the displacement plane, judging total ACJ displacement in any direction rather than trying to quantify vertical and/or horizontal displacement. When utilized clinically, the circles measurement is a single measurement calculated as the difference between values recorded for the injured and uninjured sides. Validation of the circles measurement was performed using lateral Alexander radiographs (including ±20° projection error in all planes) and computed tomography of standardized ACJ injury simulations. We assessed inter- and intrarater reliability, convergent validity, and discriminant validity of the circles measurement and subsequently generated a classification of ACJ injury based on displacement.

RESULTS

Reliability and validity of the circles measurement was excellent throughout. Interrater reliability (ICC [intraclass correlation coefficient] [2,1], 95% CI; n = 78; 4 observers) was 0.976 (0.964-0.985). Intrarater reliability (ICC [2,1]; 95% CI; n = 78; 2 measures) was 0.998 (0.996-0.998). Convergent validity (Pearson correlation coefficient, r) was 0.970 for ideal radiographs and 0.889 with ±20° projection error in all planes. Discriminant validity, with 1-way analysis of variance, showed a P value of <.0001 and effect size (η2) of 0.960, with the ability to distinguish between the previously defined stable (Rockwood IIIA) and unstable (Rockwood IIIB) injuries. The results permitted objective, statistically sound parameters for the proposed ABC classification system.

CONCLUSION

The circles measurement is a simple, reliable, valid, accurate, and resilient parameter for assessing ACJ displacement and can be used in conjunction with the proposed ABC classification to define ACJ injuries more accurately and objectively than previously described.

CLINICAL RELEVANCE

This novel parameter has the potential to standardize the initial assessment and possibly the subsequent clinical management of ACJ injuries, in addition to providing a standardized measure for future research.
Date of Publication
2021-05
Publication Type
article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
acromioclavicular joint clinical assessment/grading scales general general sports trauma imaging and radiology shoulder
Language(s)
en
Contributor(s)
Murphy, Richard J
Moor, Beat Kaspar
Hôpital du Valais
Lesniewski, Piotr J
Hayoz, Annabel
Alcantara, Wolfan
Zumstein, Matthias
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Additional Credits
Hôpital du Valais
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Series
The American journal of sports medicine
Publisher
Sage
ISSN
1552-3365
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 4f1f0f [ 1.12. 12:07]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo