  2. Publications
  3. Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.
 

Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.

Options
  • Details
BORIS DOI
10.7892/boris.132051
Date of Publication
May 2019
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Contributor
Koh, In Jun
Park, Il Jung
Lin, Charles C
Patel, Nilay A
Chalmers, Christen E
Maniglio, Mauro
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
McGarry, Michelle H
Lee, Thay Q
Subject(s)

600 - Technology::610...

Series
Knee surgery, sports traumatology, arthroscopy
ISSN or ISBN (if monograph)
0942-2056
Publisher
Springer-Verlag
Language
English
Publisher DOI
10.1007/s00167-018-5270-2
PubMed ID
30370439
Uncontrolled Keywords

Kinematic alignment M...

Description
PURPOSE

The implant positioning for kinematically aligned total knee arthroplasty (TKA) differs fundamentally from conventional mechanically aligned TKA. This difference may affect patellofemoral (PF) biomechanics after TKA. This cadaveric study tested the hypothesis that kinematically aligned TKA would restore PF biomechanics to the native condition better than mechanically aligned TKA.

METHODS

Seven pairs (14 knees) of fresh-frozen cadavers were tested. All specimens were mounted on a customized knee-testing system and digitized using a Microscribe 3DLX instrument (Revware Inc., Raleigh, NC, USA) to measure patellar kinematics in terms of patellar varus/valgus rotation, medial/lateral position, flexion/extension rotation and proximal/distal position at knee flexion angles of 0°, 30°, 60°, 90°, and 120°. The medial and lateral PF joint contact pressure distributions at 120° of knee flexion were measured using a K-scan system (Tekscan Inc., Boston, MA, USA). All patellae remained unresurfaced. For each pair, one knee was randomly assigned to kinematically aligned TKA and the other to mechanically aligned TKA performed using the conventional measured resection technique. During kinematically aligned TKA, the amount of femur and tibia resected was equivalent to implant thickness to maintain the patient-specific joint line. All patellar kinematics were measured and compared between the native condition and after surgery.

RESULTS

The patellae of mechanically aligned TKA rotated more valgus and was positioned more laterally compared with those of kinematically aligned TKA at knee flexion angles ≥ 90°. Neither the patellar flexion/extension rotation nor the proximal/distal position differed between either prosthetic knee design and the native knee at all flexion angles. The contact pressure distribution between the medial and lateral PF joint after kinematically aligned TKA were similar to those of the native knee, while the lateral PF joint contact pressure after mechanically aligned TKA was higher than that of the native knee (p = 0.038).

CONCLUSIONS

Kinematically aligned TKA better restores patellar kinematics and PF contact pressure distribution to the native condition than mechanically aligned TKA during deep knee flexion. These findings provide clues to understand why kinematically aligned TKA is associated with less anterior knee pain and better PF functional performance compared to mechanically aligned TKA. Patients undergoing kinematically aligned TKA may experience a more normal feeling during deep knee flexion activities.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/181279
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Koh2019_Article_KinematicallyAlignedTotalKneeA.pdftextAdobe PDF1.24 MBpublisherpublishedOpen
BORIS Portal
Bern Open Repository and Information System