• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Projects
  • Research Data
  • Organizations
  • Researchers
  • Theses
  • More
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Computed tomography-based automated 3D measurement of femoral version: Validation against standard 2D measurements in symptomatic patients.
 

Computed tomography-based automated 3D measurement of femoral version: Validation against standard 2D measurements in symptomatic patients.

Options
  • Details
  • Files
BORIS DOI
10.48350/196318
Publisher DOI
10.1002/jor.25865
PubMed ID
38678375
Description
To validate 3D methods for femoral version measurement, we asked: (1) Can a fully automated segmentation of the entire femur and 3D measurement of femoral version using a neck based method and a head-shaft based method be performed? (2) How do automatic 3D-based computed tomography (CT) measurements of femoral version compare to the most commonly used 2D-based measurements utilizing four different landmarks? Retrospective study (May 2017 to June 2018) evaluating 45 symptomatic patients (57 hips, mean age 18.7 ± 5.1 years) undergoing pelvic and femoral CT. Femoral version was assessed using four previously described methods (Lee, Reikeras, Tomczak, and Murphy). Fully-automated segmentation yielded 3D femur models used to measure femoral version via femoral neck- and head-shaft approaches. Mean femoral version with 95% confidence intervals, and intraclass correlation coefficients were calculated, and Bland-Altman analysis was performed. Automatic 3D segmentation was highly accurate, with mean dice coefficients of 0.98 ± 0.03 and 0.97 ± 0.02 for femur/pelvis, respectively. Mean difference between 3D head-shaft- (27.4 ± 16.6°) and 3D neck methods (12.9 ± 13.7°) was 14.5 ± 10.7° (p < 0.001). The 3D neck method was closer to the proximal Lee (-2.4 ± 5.9°, -4.4 to 0.5°, p = 0.009) and Reikeras (2 ± 5.6°, 95% CI: 0.2 to 3.8°, p = 0.03) methods. The 3D head-shaft method was closer to the distal Tomczak (-1.3 ± 7.5°, 95% CI: -3.8 to 1.1°, p = 0.57) and Murphy (1.5 ± 5.4°, -0.3 to 3.3°, p = 0.12) methods. Automatic 3D neck-based-/head-shaft methods yielded femoral version angles comparable to the proximal/distal 2D-based methods, when applying fully-automated segmentations.
Date of Publication
2024-10
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
deep learning femoral osteotomy femoral version hip arthroscopy
Language(s)
en
Contributor(s)
Schmaranzer, Florian
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie (DIPR)
Movahhedi, Mohammadreza
Singh, Mallika
Kallini, Jennifer R
Nanavati, Andreas Kavin
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Steppacher, Simon Damian
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Heimann, Alexander F
Kiapour, Ata M
Novais, Eduardo N
Additional Credits
Universitätsklinik für Orthopädische Chirurgie und Traumatologie
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie (DIPR)
Series
Journal of orthopaedic research
Publisher
Wiley
ISSN
0736-0266
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 7bc660 [30.01. 11:07]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo