Combining Glucose Monitoring and Insulin Infusion in an Integrated Device: A Narrative Review of Challenges and Proposed Solutions.

Options
  • Details
BORIS DOI
10.48350/186960
Date of Publication
2025
Publication Type
Article
Division/Institute

ARTORG Center for Bio...

Contributor
Schoemaker, Michael
Martensson, Anna
Mader, Julia K
Nørgaard, Kirsten
Freckmann, Guido
Benhamou, Pierre-Yves
Diem, Peter
ARTORG Center for Biomedical Engineering Research
Heinemann, Lutz
Subject(s)

500 - Science::570 - ...

600 - Technology::610...

Series
Journal of diabetes science and technology
ISSN or ISBN (if monograph)
1932-2968
Publisher
Sage
Language
English
Publisher DOI
10.1177/19322968231203237
PubMed ID
37798963
Uncontrolled Keywords

accuracy automated in...

Description
The introduction of automated insulin delivery (AID) systems has enabled increasing numbers of individuals with type 1 diabetes (T1D) to improve their glycemic control largely. However, use of AID systems is limited due to their complexity and costs associated. The user must wear both a continuously monitoring glucose system and an insulin infusion pump. The glucose sensor and the insulin catheter must be inserted at two different body sites using different insertion devices. In addition, the user must pair and manage the different systems. These communicate with the AID software implemented on the pump or on a third device such as a dedicated display device or smart phone application. These components might be developed and commercialized by different manufacturers, which in turn can cause difficulties for patients seeking technical support. A possible solution to these challenges would be to integrate the glucose sensor and insulin catheter into a single device. This would allow the glucose sensor and insulin catheter to be inserted simultaneously, eliminating the need for pairing, and simplifying system management. In recent years, different technologies have been developed and evaluated in clinical investigations that combine the glucose sensor and the insulin catheter in one platform. The consistent finding of all these studies is that integration has no adverse effect on insulin infusion and glucose measurements provided that certain conditions are met. In this review, we discuss the perceived challenges of such an approach and discuss possible solutions that have been proposed.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/170495
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
schoemaker-et-al-2023-combining-glucose-monitoring-and-insulin-infusion-in-an-integrated-device-a-narrative-review-of.pdftextAdobe PDF777.65 KBAttribution-NonCommercial (CC BY-NC 4.0)publishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 960e9e [21.08. 13:49]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo