  3. Biogenic polymer-based patches for congenital cardiac surgery: a feasibility study.
 

Biogenic polymer-based patches for congenital cardiac surgery: a feasibility study.

Options
  • Details
  • Files
BORIS DOI
10.48350/184637
Publisher DOI
10.3389/fcvm.2023.1164285
PubMed ID
37424903
Description
OBJECTIVE

Currently used patch materials in congenital cardiac surgery do not grow, renew, or remodel. Patch calcification occurs more rapidly in pediatric patients eventually leading to reoperations. Bacterial cellulose (BC) as a biogenic polymer offers high tensile strength, biocompatibility, and hemocompatibility. Thus, we further investigated the biomechanical properties of BC for use as patch material.

METHODS

The BC-producing bacteria Acetobacter xylinum were cultured in different environments to investigate optimal culturing conditions. For mechanical characterization, an established method of inflation for biaxial testing was used. The applied static pressure and deflection height of the BC patch were measured. Furthermore, a displacement and strain distribution analysis was performed and compared to a standard xenograft pericardial patch.

RESULTS

The examination of the culturing conditions revealed that the BC became homogenous and stable when cultivated at 29°C, 60% oxygen concentration, and culturing medium exchange every third day for a total culturing period of 12 days. The estimated elastic modulus of the BC patches ranged from 200 to 530 MPa compared to 230 MPa for the pericardial patch. The strain distributions, calculated from preloaded (2 mmHg) to 80 mmHg inflation, show BC patch strains ranging between 0.6% and 4%, which was comparable to the pericardial patch. However, the pressure at rupture and peak deflection height varied greatly, ranging from 67 to around 200 mmHg and 0.96 to 5.28 mm, respectively. The same patch thickness does not automatically result in the same material properties indicating that the manufacturing conditions have a significant impact on durability.

CONCLUSIONS

BC patches can achieve comparable results to pericardial patches in terms of strain behavior as well as in the maximum applied pressure that can be withstood without rupture. Bacterial cellulose patches could be a promising material worth further research.
Date of Publication
2023
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Keyword(s)
biogenic polymers biomedical engineering congenital innovation patch
Language(s)
en
Contributor(s)
Richert, Emma
Nienhaus, Andrea Gabriela
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
Jahren, Silje Ekrollorcid-logo
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
Gazdhar, Amiq
Department for BioMedical Research, Forschungsgruppe Pneumologie (Erwachsene)
Grab, Maximilian
Hörer, Jürgen
Carrel, Thierry
Obrist, Dominikorcid-logo
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
Heinisch, Paul Philipp
Additional Credits
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
Department for BioMedical Research, Forschungsgruppe Pneumologie (Erwachsene)
Series
Frontiers in cardiovascular medicine
Publisher
Frontiers
ISSN
2297-055X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 9f4e9a [ 5.02. 18:48]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo