• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Biomechanical performance of a novel light-curable bone fixation technique.
 

Biomechanical performance of a novel light-curable bone fixation technique.

Options
  • Details
  • Files
BORIS DOI
10.48350/183273
Publisher DOI
10.1038/s41598-023-35706-3
PubMed ID
37291148
Description
Traumatic bone fractures are often debilitating injuries that may require surgical fixation to ensure sufficient healing. Currently, the most frequently used osteosynthesis materials are metal-based; however, in certain cases, such as complex comminuted osteoporotic fractures, they may not provide the best solution due to their rigid and non-customizable nature. In phalanx fractures in particular, metal plates have been shown to induce joint stiffness and soft tissue adhesions. A new osteosynthesis method using a light curable polymer composite has been developed. This method has demonstrated itself to be a versatile solution that can be shaped by surgeons in situ and has been shown to induce no soft tissue adhesions. In this study, the biomechanical performance of AdhFix was compared to conventional metal plates. The osteosyntheses were tested in seven different groups with varying loading modality (bending and torsion), osteotomy gap size, and fixation type and size in a sheep phalanx model. AdhFix demonstrated statistically higher stiffnesses in torsion (64.64 ± 9.27 and 114.08 ± 20.98 Nmm/° vs. 33.88 ± 3.10 Nmm/°) and in reduced fractures in bending (13.70 ± 2.75 Nm/mm vs. 8.69 ± 1.16 Nmm/°), while the metal plates were stiffer in unreduced fractures (7.44 ± 1.75 Nm/mm vs. 2.70 ± 0.72 Nmm/°). The metal plates withstood equivalent or significantly higher torques in torsion (534.28 ± 25.74 Nmm vs. 614.10 ± 118.44 and 414.82 ± 70.98 Nmm) and significantly higher bending moments (19.51 ± 2.24 and 22.72 ± 2.68 Nm vs. 5.38 ± 0.73 and 1.22 ± 0.30 Nm). This study illustrated that the AdhFix platform is a viable, customizable solution that is comparable to the mechanical properties of traditional metal plates within the range of physiological loading values reported in literature.
Date of Publication
2023-06-08
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Language(s)
en
Contributor(s)
Schwarzenberg, Peter
Colding-Rasmussen, Thomas
Hutchinson, Daniel J
Mischler, Dominic
Horstmann, Peter
Petersen, Michael Mørk
Jacobsen, Stine
Pastor, Tatjana
Universitätsklinik für Plastische- und Handchirurgie, Handchirurgie und Chirurgie der peripheren Nerven
Malkoch, Michael
Wong, Christian
Varga, Peter
Additional Credits
Universitätsklinik für Plastische- und Handchirurgie, Handchirurgie und Chirurgie der peripheren Nerven
Series
Scientific Reports
Publisher
Nature Publishing Group
ISSN
2045-2322
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 9f4e9a [ 5.02. 18:48]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo