• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. A survey of practice patterns for real-time intrafractional motion-management in particle therapy.
 

A survey of practice patterns for real-time intrafractional motion-management in particle therapy.

Options
  • Details
  • Files
BORIS DOI
10.48350/182183
Publisher DOI
10.1016/j.phro.2023.100439
PubMed ID
37124167
Description
BACKGROUND AND PURPOSE

Organ motion compromises accurate particle therapy delivery. This study reports on the practice patterns for real-time intrafractional motion-management in particle therapy to evaluate current clinical practice and wishes and barriers to implementation.

MATERIALS AND METHODS

An institutional questionnaire was distributed to particle therapy centres worldwide (7/2020-6/2021) asking which type(s) of real-time respiratory motion management (RRMM) methods were used, for which treatment sites, and what were the wishes and barriers to implementation. This was followed by a three-round DELPHI consensus analysis (10/2022) to define recommendations on required actions and future vision. With 70 responses from 17 countries, response rate was 100% for Europe (23/23 centres), 96% for Japan (22/23) and 53% for USA (20/38).

RESULTS

Of the 68 clinically operational centres, 85% used RRMM, with 41% using both rescanning and active methods. Sixty-four percent used active-RRMM for at least one treatment site, mostly with gating guided by an external marker. Forty-eight percent of active-RRMM users wished to expand or change their RRMM technique. The main barriers were technical limitations and limited resources. From the DELPHI analysis, optimisation of rescanning parameters, improvement of motion models, and pre-treatment 4D evaluation were unanimously considered clinically important future focus. 4D dose calculation was identified as the top requirement for future commercial treatment planning software.

CONCLUSION

 A majority of particle therapy centres have implemented RRMM. Still, further development and clinical integration were desired by most centres. Joint industry, clinical and research efforts are needed to translate innovation into efficient workflows for broad-scale implementation.
Date of Publication
2023-04
Publication Type
Article
Subject(s)
500 - Science::530 - Physics
600 - Technology::610 - Medicine & health
Keyword(s)
Image-guided particle therapy Intrafraction motion Particle/proton therapy Real-time respiratory motion management Rescanning
Language(s)
en
Contributor(s)
Zhang, Ye
Trnkova, Petra
Toshito, Toshiyuki
Heijmen, Ben
Richter, Christian
Aznar, Marianne
Albertini, Francesca
Bolsi, Alexandra
Daartz, Juliane
Bertholet, Jennyorcid-logo
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik
Universitätsklinik für Radio-Onkologie
Knopf, Antje
Additional Credits
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik
Series
Physics and imaging in radiation oncology
Publisher
Elsevier
ISSN
2405-6316
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 9f4e9a [ 5.02. 18:48]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo