  3. Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in vitro study.
 

Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in vitro study.

Options
  • Details
  • Files
BORIS DOI
10.48350/179269
Publisher DOI
10.1016/j.prosdent.2023.01.027
PubMed ID
36841708
Description
STATEMENT OF PROBLEM

The scanning strategy used when making complete arch digital scans affects the accuracy of the scan, and the accuracy of the strategy may be influenced by the scanner used. However, these effects have not been investigated thoroughly with complete arch edentulous scanning.

PURPOSE

The purpose of this in vitro study was to determine the effect of scanning strategies and the scanned arch on the accuracy of complete arch edentulous scans using 2 intraoral scanner (IOS) systems.

MATERIAL AND METHODS

Two IOSs were used (TRIOS 4 and Emerald S) to scan maxillary and mandibular typodonts using 6 scanning strategies (test scans), and conventional impressions of both arches were also made. By using a metrology software program, test scans were superimposed onto a reference scan, and the root mean square (RMS) of the absolute deviation values was calculated to express trueness. The sample with the best trueness was used as reference onto which the remaining samples from the same group were superimposed, and the RMS of the absolute deviation values was calculated to express precision. Statistical modeling was applied using the fixed effects models (α=.05).

RESULTS

The main effects of scanner and strategy significantly impacted the trueness RMS values (P<.001), with significant interactions between them (P=.012). The main effects of scanner, strategy, and arch significantly impacted the precision of RMS values (P=.004), (P=.033), and (P=.023). Conventional impressions and the TRIOS 4 scanner had comparable accuracy, while the Emerald S scanner was inferior to both. P-O-B had the highest overall accuracy and strategy ZZ had the worst. Better precision was found with the maxillary arch.

CONCLUSIONS

The scanner type and scanning strategy significantly impacted the accuracy of the digital scans of completely edentulous arches, with a significant interaction between scanner and strategy. The arch being scanned had a significant effect on scan precision but not on scan trueness.
Date of Publication
2024-06
Publication Type
Article
Subject(s)
600 - Technology::610 - Medicine & health
Language(s)
en
Contributor(s)
Jamjoom, Faris Z
Aldghim, Adhwaa
Aldibasi, Omar
Yilmaz, Burak
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Additional Credits
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
The journal of prosthetic dentistry
Publisher
Elsevier
ISSN
1097-6841
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 7bc660 [30.01. 11:07]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo