10.1136/jnnp-2015-310853
PubMed ID
26285586
Description
OBJECTIVE

Spontaneous intracranial hypotension (SIH) is most commonly caused by cerebrospinal fluid (CSF) leakage. Therefore, we hypothesised that patients with orthostatic headache (OH) would show decreased optic nerve sheath diameter (ONSD) during changes from supine to upright position.

METHODS

Transorbital B-mode ultrasound was performed employing a high-frequency transducer for ONSD measurements in the supine and upright positions. Absolute values and changes of ONSD from supine to upright were assessed. Ultrasound was performed in 39 SIH patients, 18 with OH and 21 without OH, and in 39 age-matched control subjects. The control group comprised 20 patients admitted for back surgery without headache or any orthostatic symptoms, and 19 healthy controls.

RESULTS

In supine position, mean ONSD (±SD) was similar in patients with (5.38±0.91 mm) or without OH (5.48±0.89 mm; p=0.921). However, in upright position, mean ONSD was different between patients with (4.84±0.99 mm) and without OH (5.53±0.99 mm; p=0.044). Furthermore, the change in ONSD from supine to upright position was significantly greater in SIH patients with OH (-0.53±0.34 mm) than in SIH patients without OH (0.05±0.41 mm; p≤0.001) or in control subjects (0.01±0.38 mm; p≤0.001; area under the curve: 0.874 in receiver operating characteristics analysis).

CONCLUSIONS

Symptomatic patients with SIH showed a significant decrease of ONSD, as assessed by ultrasound, when changing from the supine to the upright position. Ultrasound assessment of the ONSD in two positions may be a novel, non-invasive tool for the diagnosis and follow-up of SIH and for elucidating the pathophysiology of SIH.
Date of Publication
2015-08-18
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Fichtner, Jens
Universitätsklinik für Neurochirurgie
Ulrich, Christian Thomas
Universitätsklinik für Neurochirurgie
Fung, Christian
Universitätsklinik für Neurochirurgie
Knüppel, Christin
Veitweber, Martina
Jilch, Astrid
Schucht, Philippe
Universitätsklinik für Neurochirurgie
Ertl, Michael
Schömig, Beate
Gralla, Jan
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Z'Graggen, Werner Josef
Universitätsklinik für Neurochirurgie
Bernasconi, Corrado Angelo
Universitätsklinik für Neurologie
Mattle, Heinrich
Universitätsklinik für Neurologie
Schlachetzki, Felix
Raabe, Andreas
Universitätsklinik für Neurochirurgie
Beck, Jürgen
Universitätsklinik für Neurochirurgie
Additional Credits
Universitätsklinik für Neurochirurgie
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Universitätsklinik für Neurologie
Series
Journal of neurology, neurosurgery and psychiatry
Publisher
BMJ Publishing Group
ISSN
0022-3050
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: f3f97c [20.03. 14:41]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo