Complications and treatment errors in implant positioning in the aesthetic zone: Diagnosis and possible solutions.
Options
BORIS DOI
Date of Publication
 June 2023 
Publication Type
Article
Division/Institute
Subject(s)
Series
Periodontology 2000
ISSN or ISBN (if monograph)
1600-0757
Publisher
Wiley
Language
English
Publisher DOI
PubMed ID
36683018
Uncontrolled Keywords
Description
Incorrect implant positioning can lead to functional and aesthetic compromise. Implant positioning errors can occur in three dimensions: mesiodistal, corono-apical, and orofacial. Treatment solutions to manage adverse outcomes through positioning errors require an understanding of the underlying conditions and of those factors that may have led to the error being committed in the first place. These types of complications usually occur because of human factors. If errors do occur with adverse aesthetic outcomes, they are difficult and sometimes impossible to correct. Connective tissue grafts to reverse recession defects are only feasible in defined situations. The option to remove and replace the implant may be the only recourse, provided the removal process does not further compromise the site. Error in judgment by the clinician.
File(s)
| File | File Type | Format | Size | License | Publisher/Copright statement | Content | |
|---|---|---|---|---|---|---|---|
| Periodontology_2000_-_2023_-_Chen_-_Complications_and_treatment_errors_in_implant_positioning_in_the_aesthetic_zone_.pdf | text | Adobe PDF | 12.58 MB | Attribution (CC BY 4.0) | published |