• LOGIN
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publication
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. A new tool based on two micromanipulators facilitates the handling of ultrathin cryosection ribbons
 

A new tool based on two micromanipulators facilitates the handling of ultrathin cryosection ribbons

Options
  • Details
BORIS DOI
10.7892/boris.46869
Date of Publication
January 2014
Publication Type
Article
Division/Institute

Institut für Anatomie...

Author
Studer, Daniel Franz
Institut für Anatomie
Klein, Alycia
Iacovache, Mircea Ioan
Institut für Anatomie
Gnaegi, Helmut
Zuber, Benoîtorcid-logo
Institut für Anatomie
Subject(s)

600 - Technology::610...

Series
Journal of structural biology
ISSN or ISBN (if monograph)
1047-8477
Publisher
Elsevier
Language
English
Publisher DOI
10.1016/j.jsb.2013.11.005
PubMed ID
24269483
Uncontrolled Keywords

Cryo-electron microsc...

Description
A close to native structure of bulk biological specimens can be imaged by cryo-electron microscopy of vitreous sections (CEMOVIS). In some cases structural information can be combined with X-ray data leading to atomic resolution in situ. However, CEMOVIS is not routinely used. The two critical steps consist of producing a frozen section ribbon of a few millimeters in length and transferring the ribbon onto an electron microscopy grid. During these steps, the first sections of the ribbon are wrapped around an eyelash (unwrapping is frequent). When a ribbon is sufficiently attached to the eyelash, the operator must guide the nascent ribbon. Steady hands are required. Shaking or overstretching may break the ribbon. In turn, the ribbon immediately wraps around itself or flies away and thereby becomes unusable. Micromanipulators for eyelashes and grids as well as ionizers to attach section ribbons to grids were proposed. The rate of successful ribbon collection, however, remained low for most operators. Here we present a setup composed of two micromanipulators. One of the micromanipulators guides an electrically conductive fiber to which the ribbon sticks with unprecedented efficiency in comparison to a not conductive eyelash. The second micromanipulator positions the grid beneath the newly formed section ribbon and with the help of an ionizer the ribbon is attached to the grid. Although manipulations are greatly facilitated, sectioning artifacts remain but the likelihood to investigate high quality sections is significantly increased due to the large number of sections that can be produced with the reported tool.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/118132
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Studer_Micromanipulators_2014.pdftextAdobe PDF1.02 MBpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: b407eb [23.05. 15:47]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo