  3. The influence of pit and fissure sealants on infrared fluorescence measurements
 

The influence of pit and fissure sealants on infrared fluorescence measurements

Options
  • Details
  • Files
BORIS DOI
10.48350/26818
Publisher DOI
10.1159/000151327
PubMed ID
18701822
Description
The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device.
Date of Publication
2008
Publication Type
Article
Language(s)
en
Contributor(s)
Diniz, M B
De Almeida Rodrigues, Jonas
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung
Hug-Grütter, Isabel Gabriella
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung
Cordeiro, R C L
Lussi, Adrian
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung
Additional Credits
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung
Series
Caries research
Publisher
Karger
ISSN
0008-6568
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 9f4e9a [ 5.02. 18:48]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo