  2. Publications
  3. A quantitative phenytoin GC-MS method and it's validation for samples from human ex situ brain microdialysis, blood and saliva using solid-phase extraction
 

A quantitative phenytoin GC-MS method and it's validation for samples from human ex situ brain microdialysis, blood and saliva using solid-phase extraction

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.44473
Publisher DOI
10.1093/jat/bks137
PubMed ID
23325763
Description
This study describes the development and validation of a gas chromatography-mass spectrometry (GC-MS) method to identify and quantitate phenytoin in brain microdialysate, saliva and blood from human samples.
A solid-phase extraction (SPE) was performed with a nonpolar C8-SCX column. The eluate was evaporated with nitrogen (50°C) and derivatized with trimethylsulfonium hydroxide before GC-MS analysis. As the internal standard, 5-(p-methylphenyl)-5-phenylhydantoin was used. The MS was run in scan mode and the identification was made with three ion fragment masses. All peaks were identified with MassLib. Spiked phenytoin samples showed recovery after SPE of ≥94%. The calibration curve (phenytoin 50 to 1,200 ng/mL, n = 6, at six concentration levels) showed good linearity and correlation (r² > 0.998). The limit of detection was 15 ng/mL; the limit of quantification was 50 ng/mL. Dried extracted samples were stable within a 15% deviation range for ≥4 weeks at room temperature. The method met International Organization for Standardization standards and was able to detect and quantify phenytoin in different biological matrices and patient samples. The GC-MS method with SPE is specific, sensitive, robust and well reproducible, and is therefore an appropriate candidate for the pharmacokinetic assessment of phenytoin concentrations in different human biological samples.
Date of Publication
2013
Publication Type
Article
Subject(s)
500 Science > 540 Chemistry
Language(s)
en
Contributor(s)
Hösli, Raphael
Tobler, Andrea
König, Stefan
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Mühlebach, Stefan
Additional Credits
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Series
Journal of analytical toxicology
Publisher
Oxford University Press
ISSN
0146-4760
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo