• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Direct Comparison of Cardiac Troponin T and I Using a Uniform and a Sex-Specific Approach in the Detection of Functionally Relevant Coronary Artery Disease.
 

Direct Comparison of Cardiac Troponin T and I Using a Uniform and a Sex-Specific Approach in the Detection of Functionally Relevant Coronary Artery Disease.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.126336
Publisher DOI
10.1373/clinchem.2018.286971
PubMed ID
30097496
Description
BACKGROUND

We aimed to directly compare high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT) in the detection of functionally relevant coronary artery disease (fCAD).

METHODS

Consecutive patients referred with clinical suspicion of fCAD and no structural heart disease other than coronary artery disease were included. The presence of fCAD was based on rest/stress myocardial perfusion single-photon emission computed tomography/computed tomography and coronary angiography. hs-cTnI and hs-cTnT concentrations were measured in a blinded fashion. Diagnostic accuracy was quantified using the area under the ROC curve (AUC) and evaluated both for uniform use in all patients and for sex-specific use in women and men separately. The prognostic end point was major adverse cardiac events (MACEs; cardiovascular death or myocardial infarction) within 2 years. For the prognostic performance, we used a multivariable model comparison with the Akaike information criterion (AIC).

RESULTS

fCAD was detected in 613 of 2062 patients (29.7%) overall, 112 of 664 of women (16.9%), and 501 of 1398 of men (35.8%). hs-cTnI and hs-cTnT had comparable diagnostic accuracy when assessed for uniform use in all patients (AUC, 0.68 vs 0.66; = 0.107) and separately in women (AUC, 0.68 vs 0.63; = 0.068) and men (AUC, 0.65 vs 0.64; = 0.475). However, women required lower rule-out cutoffs to achieve high sensitivity, and men needed higher rule-in cutoffs to achieve high specificity. hs-cTnI and hs-cTnT were strongly and independently associated with MACE within 2 years ( < 0.001), with comparable prognostic accuracies by the AIC.

CONCLUSIONS

hs-cTnI and hs-cTnT provide moderate and comparable diagnostic accuracy. Sex-specific cutoffs may be preferred. The prognostic utility of both troponins is comparable.
Date of Publication
2018-11
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Mueller, Deborah
Puelacher, Christian
Honegger, Ursina
Walter, Joan E
Badertscher, Patrick
Schaerli, Nicolas
Strebel, Ivo
Twerenbold, Raphael
Boeddinghaus, Jasper
Nestelberger, Thomas
Hollenstein, Christina
du Fay de Lavallaz, Jeanne
Jeger, Raban
Kaiser, Christoph
Wild, Damian
Rentsch, Katharina
Buser, Andreas
Zellweger, Michael
Reichlin, Tobias Romanorcid-logo
Universitätsklinik für Kardiologie
Mueller, Christian
Additional Credits
Universitätsklinik für Kardiologie
Series
Clinical chemistry
Publisher
American Association for Clinical Chemistry
ISSN
0009-9147
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo