• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Biomechanical evaluation of three different fixation methods in tibial tuberosity transposition in cats
 

Biomechanical evaluation of three different fixation methods in tibial tuberosity transposition in cats

Options
  • Details
  • Files
BORIS DOI
10.48620/92725
Publisher DOI
10.1177/1098612x251381489
PubMed ID
41267348
Description
Objectives
This study aimed to compare three different fixation techniques for tibial tuberosity transposition (TTT) in cats in a non-cyclic load-to-failure model. The objective was to determine whether there was a significant difference between the maximum load at failure (MLF) and stiffness between a two-pin tension band wire construct (2PTBW), a two-pin construct with a maintained distal cortical attachment (2PDA) and a two-pin construct (2P), and to report the modes of failure of each group.

Methods
Tibiae from cat cadavers (n = 40) were allocated to one of four groups: 2PTBW, 2PDA, 2P and control (no surgery). The respective technique was performed on each tibia with a vertical alignment of the pins. Biomechanical testing was performed in a non-cyclic load-to-failure model; MLF, stiffness and mode of failure were recorded. Statistical analyses included one-way ANOVA and pairwise comparisons.

Results
The 2P group had a significantly lower MLF than the 2PTBW, 2PDA and control groups (P <0.05) and a significantly lower stiffness than the 2PDA and control groups (P <0.05). There was no significant difference between 2PTBW and 2PDA. The most common mode of failure in the 2PTBW group was vertical tearing of the tibial tuberosity, while in the 2PDA group, the distal cortical attachment fractured and the pins subsequently pulled out. The 2P group most commonly failed because of pin pull-out.

Conclusions and relevance
The 2PDA technique demonstrated similar strength to the 2PTBW technique in a load-to-failure model. The 2P technique was the weakest of the three. This study provides a foundation for further clinical research.
Date of Publication
2025-11
Publication Type
Article
Keyword(s)
Medial patellar luxation
•
biomechanical testing
•
orthopaedic surgery
•
tibial tuberosity transposition
Language(s)
en
Contributor(s)
Schwarzmann, Paul
Department of Clinical Veterinary Medicine, Small Animal Clinic, Surgery
Department of Clinical Veterinary Medicine, Small Animal Clinic
Department of Clinical Veterinary Medicine
Park, Brian
Irgang, Moritz
Knell, Sebastian
Forterre, Franck
Department of Clinical Veterinary Medicine, Small Animal Clinic, Surgery
Department of Clinical Veterinary Medicine, Small Animal Clinic
Department of Clinical Veterinary Medicine
Additional Credits
Department of Clinical Veterinary Medicine
Department of Clinical Veterinary Medicine, Small Animal Clinic
Department of Clinical Veterinary Medicine, Small Animal Clinic, Surgery
Series
Journal of Feline Medicine and Surgery
Publisher
SAGE Publications
ISSN
1098-612X
1532-2750
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo