• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Fully Automated Determination of Phosphatidylethanol 16:0/18:1 and 16:0/18:2 in Dried Blood Spots.
 

Fully Automated Determination of Phosphatidylethanol 16:0/18:1 and 16:0/18:2 in Dried Blood Spots.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.131246
Publisher DOI
10.1093/jat/bkz035
PubMed ID
31062845
Description
PURPOSE

Direct alcohol markers are widely applied during abstinence monitoring, driving aptitude assessments and workplace drug testing. The most promising direct alcohol marker was found to be phosphatidylethanol (PEth). Compared to other markers it shows a long window of detection due to accumulation in blood. To facilitate and accelerate the determination of PEth in DBS, we developed a fully automated analysis approach.

METHODS

The validated and novel online-SPE-LC-MS/MS method with automated sample preparation using a CAMAG DBS-MS 500 system reduces manual sample preparation to an absolute minimum, only requiring calibration and quality control DBS.

RESULTS

During the validation process, the method showed a high extraction efficiency (>88%), linearity (correlation coefficient >0.9953), accuracy and precision (within ±15%) for the determination of PEth 16:0/18:1 and PEth 16:0/18:2. Within a run time of about 7 min, the two monitored analogs could be baseline separated. A method comparison in liquid whole blood of 28 authentic samples from alcohol use disorder patients showed a mean deviation of less than 2% and a correlation coefficient of >0.9759. The comparison with manual DBS extraction showed a mean deviation of less than 8% and a correlation coefficient of >0.9666.

CONCLUSIONS

The automated analysis of PEth in DBS can provide a fast and accurate solution for abstinence monitoring. In contrast to the manual extraction of PEth in DBS, no laborious sample preparation is required with this automated approach. Furthermore, the application of the internal standard by a spray module can compensate for extraction bias and matrix effects.
Date of Publication
2019-07-24
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Luginbühl, Marc Joel
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Institut für Rechtsmedizin (IRM)
Gaugler, Stefan
Weinmann, Wolfgang
Institut für Rechtsmedizin (IRM)
Institut für Rechtsmedizin (IRM)
Institut für Rechtsmedizin, Direktion
Additional Credits
Institut für Rechtsmedizin, Forensische Chemie und Toxikologie
Institut für Rechtsmedizin (IRM)
Series
Journal of analytical toxicology
Publisher
Oxford University Press
ISSN
0146-4760
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo