Publication:
TIMS measurements of full range of natural Ca isotopes with internally consistent fractionation correction

cris.virtual.author-orcid0000-0001-5469-1060
cris.virtual.author-orcid0000-0002-6919-0151
cris.virtual.author-orcid0000-0002-2443-8539
cris.virtual.author-orcid0000-0002-8070-8142
cris.virtualsource.author-orcida7bbfeab-5160-4560-8167-06661fc103e8
cris.virtualsource.author-orcidfffba8da-c541-4e6f-a28d-9334faa8cc57
cris.virtualsource.author-orcid2f5de103-cfa3-401d-b1a3-98833ad51afb
cris.virtualsource.author-orciddd15585d-846b-44dc-9578-799d04341281
dc.contributor.authorDèzes, Mariia Oleksiivna
dc.contributor.authorBouman, Claudia
dc.contributor.authorNägler, Frank Thomas
dc.contributor.authorMezger, Klaus
dc.contributor.authorVilla, Igor Maria
dc.date.accessioned2024-10-24T16:19:46Z
dc.date.available2024-10-24T16:19:46Z
dc.date.issued2015
dc.description.abstractThis study presents static measurements of the Ca isotopic composition of standard reference materials SRM 915 a/b on a Triton Plus™ thermal ionization mass spectrometer with a specially developed Faraday cup array allowing simultaneous measurement of 40Ca and 48Ca. The total amount of Ca in all analyses was kept < 1 µg. With this setup the measurement uncertainties were 0.06 ‰ for 40Ca/44Ca and 0.12 ‰ for 48Ca/40Ca. Measuring all isotopes simultaneously better allows to test the internal consistency of different Ca isotope abundances reported in the literature. The exponential law was observed to correct incompletely instrumental mass fractionation. An improved fractionation correction based on the exponential law is proposed. It changes the 40Ca/44Ca ratio of SRM 915a (corrected relative to 42Ca/44Ca = 0.31221; 48Ca/44Ca = 0.08871) from 47.1635 ± 0.0028 to 47.1649 ± 0.0047. The measurements of SRM 915b were performed with different analytical conditions (runs were prolonged till complete filament load depletion). Even if the 40Ca/44Ca ratio of SRM 915b, when corrected with the simple exponential law, appears different (47.1532 ± 0.0038) from that of SRM 915a, it becomes coincident (47.1613 ± 0.0028) when corrected with a second-order refinement. This supports the use of the improved exponential law to obtain internally consistent Ca isotope ratio for natural samples.
dc.description.numberOfPages9
dc.description.sponsorshipInstitut für Geologie
dc.identifier.doi10.7892/boris.75175
dc.identifier.isiWOS:000361925300010
dc.identifier.publisherDOI10.1016/j.ijms.2015.07.012
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/137582
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofInternational journal of mass spectrometry
dc.relation.issn1387-3806
dc.relation.organizationDCD5A442C18FE17DE0405C82790C4DE2
dc.subjectTIMS; Static measurement
dc.subjectCa isotopes
dc.subjectSRM915
dc.subjectMass fractionation correction
dc.subject40Ca/44Ca
dc.subject.ddc500 - Science::550 - Earth sciences & geology
dc.titleTIMS measurements of full range of natural Ca isotopes with internally consistent fractionation correction
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage68
oaire.citation.startPage60
oaire.citation.volume387
oairecerif.author.affiliationInstitut für Geologie
oairecerif.author.affiliationInstitut für Geologie
oairecerif.author.affiliationInstitut für Geologie
oairecerif.author.affiliationInstitut für Geologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.description.ispublishedpub
unibe.eprints.legacyId75175
unibe.journal.abbrevTitleINT J MASS SPECTROM
unibe.refereedTRUE
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Naumenko.pdf
Size:
1.47 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections