• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Are we ready for amyloid-related imaging abnormalities (ARIA) monitoring? A European survey among neuroradiologists and neurologists by the ESNR/EAN Working Group.
 

Are we ready for amyloid-related imaging abnormalities (ARIA) monitoring? A European survey among neuroradiologists and neurologists by the ESNR/EAN Working Group.

Options
  • Details
  • Files
BORIS DOI
10.48620/94009
Publisher DOI
10.1007/s00330-025-12214-8
PubMed ID
41493545
Description
Objectives
Amyloid-lowering immunotherapies can cause amyloid-related imaging abnormalities (ARIA), requiring brain MRI for detection and monitoring. The European Society of Neuroradiology (ESNR)/European Academy of Neurology (EAN) ARIA Working Group conducted a survey to assess European clinicians' readiness for this logistical challenge and need for further education on ARIA.Materials And Methods
An online questionnaire with 32 items (multiple choice, single best choice, and free text) was distributed to ESNR and EAN members. Between June and July 2024, we collected 422 responses from 41 European countries, including 47% neurologists and 51% (neuro)radiologists; 15% were residents, and 58% worked in academic hospitals.Results
Of respondents, 69% were familiar with the concept of ARIA, and 60% reportedly understood its risk factors. Confidence in evaluating ARIA-E (edema/effusion) and ARIA-H (hemorrhage) subtypes was reported by 60% and 69%, respectively, with (neuro)radiologists more confident than neurologists. However, 34% of respondents felt poorly equipped to meet logistical demands, and 82% lacked a dedicated ARIA imaging protocol. Key barriers included limited organizational adaptability and radiology expertise. Notably, 72% saw potential in having support by artificial intelligence approaches, and 93% expressed the wish for further training on how to monitor ARIA.Conclusions
Despite the current unavailability of amyloid-lowering therapies, European neurologists and (neuro)radiologists report reasonable ARIA awareness. There is a clear need for additional practical preparation and training in ARIA assessment, which can inform future ESNR/EAN educational initiatives.Key Points
Question Are neurologists and neuroradiologists ready for ARIA monitoring? Findings Neurologists and neuroradiologists were moderately familiar with the concept of ARIA, its risk factors, and its identification on MRI, but felt poorly equipped to meet the logistical demands. Clinical relevance With the potential introduction of amyloid-lowering therapies in European countries, identifying key barriers, such as limited organizational adaptability and radiology expertise, highlights the need for further practical preparation by clinical departments and additional training in ARIA assessment.
Date of Publication
2026-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Alzheimer
•
Amyloid-related imaging abnormalities
•
Anti-amyloid
•
MRI
Language(s)
en
Contributor(s)
Oliveira, Tiago Gil
Vernooij, Meike W
Frisoni, Giovanni B
Wiest, Roland
Institute of Diagnostic and Interventional Neuroradiology
Barkhof, Frederik
Additional Credits
Institute of Diagnostic and Interventional Neuroradiology
Series
European Radiology
Publisher
Springer
ISSN
1432-1084
0938-7994
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo