Outcomes of rotating versus pure hinge knee arthroplasty in the setting of one-stage exchange for periprosthetic joint infection.
Options
BORIS DOI
Publisher DOI
PubMed ID
38558190
Description
PURPOSE
Rotating or pure hinge knee prostheses are often used in case of periprosthetic joint infection (PJI). Five-year survival data of rotating hinge implants ranging from 52 to 90%, whereas pure hinge data are sparse. This study describes the results of both hinge knee prostheses after one-stage septic exchange.
METHODS
One hundred sixty-seven one-stage septic exchanges of a primary unconstrained total knee arthroplasty (TKA) to a cemented hinge prosthesis (117 rotating and 50 pure hinge TKAs) performed between 2008 and 2017 were retrospectively reviewed. Exclusion criteria were stem extensions or augments used in primary TKA, history of extensor mechanism reconstruction, and a follow-up less than two years after surgery. Rates of reinfection, mechanical failures, and all-cause revision-free survival data were documented.
RESULTS
At five years, the all-cause revision-free survival was 77% (95% CI 69 to 82). Thirty-one patients (19%) had further revision for aseptic reasons. In the rotating hinge group, the mechanical failure rate was more than twice as high as in the pure hinge group (13% vs 6%), significantly influenced by higher body weight. At a mean follow-up of 6.7 years, 21 (13%) patients had a reinfection and underwent a further surgery. Reinfection rates did not differ between the two groups.
CONCLUSION
The use of hinge TKA in the revision of PJI shows favourable five year infection-free and all-cause revision-free survival rates of 91% and 77%, respectively. Our study showed poorer results of the rotating hinge design. These results may help surgeons to choose proper implants in case of septic knee revision.
Rotating or pure hinge knee prostheses are often used in case of periprosthetic joint infection (PJI). Five-year survival data of rotating hinge implants ranging from 52 to 90%, whereas pure hinge data are sparse. This study describes the results of both hinge knee prostheses after one-stage septic exchange.
METHODS
One hundred sixty-seven one-stage septic exchanges of a primary unconstrained total knee arthroplasty (TKA) to a cemented hinge prosthesis (117 rotating and 50 pure hinge TKAs) performed between 2008 and 2017 were retrospectively reviewed. Exclusion criteria were stem extensions or augments used in primary TKA, history of extensor mechanism reconstruction, and a follow-up less than two years after surgery. Rates of reinfection, mechanical failures, and all-cause revision-free survival data were documented.
RESULTS
At five years, the all-cause revision-free survival was 77% (95% CI 69 to 82). Thirty-one patients (19%) had further revision for aseptic reasons. In the rotating hinge group, the mechanical failure rate was more than twice as high as in the pure hinge group (13% vs 6%), significantly influenced by higher body weight. At a mean follow-up of 6.7 years, 21 (13%) patients had a reinfection and underwent a further surgery. Reinfection rates did not differ between the two groups.
CONCLUSION
The use of hinge TKA in the revision of PJI shows favourable five year infection-free and all-cause revision-free survival rates of 91% and 77%, respectively. Our study showed poorer results of the rotating hinge design. These results may help surgeons to choose proper implants in case of septic knee revision.
Date of Publication
2024-07
Publication Type
Article
Subject(s)
Keyword(s)
Hinge knee prosthesis Knee arthroplasty One-stage septic exchange Periprosthetic joint infection Revision arthroplasty
Language(s)
en
Contributor(s)
Linke, Philip | |
Gehrke, Thorsten | |
Citak, Mustafa | |
Lausmann, Christian |
Additional Credits
Series
International orthopaedics
Publisher
Springer
ISSN
0341-2695
Access(Rights)
restricted