Inter-algorithm lesion volumetry comparison of real and 3D simulated lung lesions in CT

Options
  • Details
Publisher DOI
10.1117/12.2254219
Description
The purpose of this study was to establish volumetric exchangeability between real and computational lung lesions in CT. We compared the overall relative volume estimation performance of segmentation tools when used to measure real lesions in actual patient CT images and computational lesions virtually inserted into the same patient images (i.e., hybrid datasets). Pathologically confirmed malignancies from 30 thoracic patient cases from Reference Image Database to Evaluate Therapy Response (RIDER) were modeled and used as the basis for the comparison. Lesions included isolated nodules as well as those attached to the pleura or other lung structures. Patient images were acquired using a 16 detector row or 64 detector row CT scanner (Lightspeed 16 or VCT; GE Healthcare). Scans were acquired using standard chest protocols during a single breath-hold. Virtual 3D lesion models based on real lesions were developed in Duke Lesion Tool (Duke University), and inserted using a validated image-domain insertion program. Nodule volumes were estimated using multiple commercial segmentation tools (iNtuition, TeraRecon, Inc., Syngo.via, Siemens Healthcare, and IntelliSpace, Philips Healthcare). Consensus based volume comparison showed consistent trends in volume measurement between real and virtual lesions across all software. The average percent bias (± standard error) shows -9.2±3.2% for real lesions versus -6.7±1.2% for virtual lesions with tool A, 3.9±2.5% and 5.0±0.9% for tool B, and 5.3±2.3% and 1.8±0.8% for tool C, respectively. Virtual lesion volumes were statistically similar to those of real lesions (< 4% difference) with p >.05 in most cases. Results suggest that hybrid datasets had similar inter-algorithm variability compared to real datasets.
Date of Publication
2017-03-09
Publication Type
Conference Item
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Flohr, Thomas G.
Lo, Joseph Y.
Gilat Schmidt, Taly
Robins, Marthony
Solomon, Justin
Hoye, Jocelyn
Smith, Taylor
Ebner, Lukas
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Lehrkörper, Medizinische Fakultät
Samei, Ehsan
Additional Credits
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Series
Proceedings of SPIE - International Society for Optical Engineering
Publisher
SPIE
ISSN
0277-786X
Title of Event
SPIE Medical Imaging
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo