• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Substrate-Based Ablation Versus Ablation Guided by Activation and Entrainment Mapping for Ventricular Tachycardia: A Systematic Review and Meta-Analysis.
 

Substrate-Based Ablation Versus Ablation Guided by Activation and Entrainment Mapping for Ventricular Tachycardia: A Systematic Review and Meta-Analysis.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.95018
Publisher DOI
10.1111/jce.13088
PubMed ID
27574120
Description
INTRODUCTION

Substrate-based ablation for scar-related ventricular tachycardia (VT) has gained prominence: however, there is limited data comparing it to ablation guided predominantly by activation and entrainment mapping of inducible and hemodynamically tolerated VTs. We compared the acute procedural efficacy and outcomes of predominantly substrate-based ablation versus ablation guided predominantly by activation and entrainment mapping.

METHODS AND RESULTS

Database searches through April 2016 identified 6 eligible studies (enrolling 403 patients, with 1 randomized study) comparing the 2 strategies. The relative risk of VT recurrence at follow-up was assessed as the primary outcome using a random-effects meta-analysis. Secondary endpoints of acute success (based on noninducibility of VT), procedural complications, and mortality were assessed using weighted mean difference with the random effects model. At a median follow-up of 18 months, the relative risk (RR) of VT recurrence was not significantly different with substrate-based versus activation/entrainment guided VT ablation (0.72, 95% confidence interval [CI] 0.44-1.18), P = 0.2). Acute success (RR 1.02, 95% CI 0.95-1.1, P = 0.6), procedural complications (RR 0.8, 95% CI 0.35-1.82, P = 0.5) cardiovascular mortality and total mortality did not differ significantly (RR 0.83, 95% CI 0.38-1.79, P = 0.6 and RR 0.76, 95% CI 0.36-1.59, P = 0.5, respectively).

CONCLUSIONS

This meta-analysis demonstrates similar acute procedural efficacy, and complications, VT recurrence and mortality rates when comparing a predominantly substrate-based ablation strategy to a strategy guided predominantly by activation and entrainment mapping of inducible and hemodynamically tolerated VTs.
Date of Publication
2016-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
activation mapping
•
catheter ablation
•
entrainment mapping
•
meta-analysis
•
substrate mapping
•
ventricular tachycardia
Language(s)
en
Contributor(s)
Kumar, Saurabh
Baldinger, Samuel Hannesorcid-logo
Universitätsklinik für Kardiologie
Romero, Jorge
Fujii, Akira
Mahida, Saagar N
Tedrow, Usha B
Stevenson, William G
Additional Credits
Universitätsklinik für Kardiologie
Series
Journal of cardiovascular electrophysiology
Publisher
Wiley-Blackwell
ISSN
1045-3873
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo