• LOGIN
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publication
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Direct observation of liquid crystals using cryo-TEM: Specimen preparation and low-dose imaging
 

Direct observation of liquid crystals using cryo-TEM: Specimen preparation and low-dose imaging

Options
  • Details
BORIS DOI
10.7892/boris.58859
Date of Publication
October 2014
Publication Type
Article
Division/Institute

Institut für Anatomie...

Author
Gao, Min
Kim, Young-Ki
Zhang, Cuiyu
Borshch, Volodymyr
Zhou, Shuang
Park, Heung-Shik
Jákli, Antal
Lavrentovich, Oleg D
Tamba, Maria-Gabriela
Kohlmeier, Alexandra
Mehl, Georg H
Weissflog, Wolfgang
Studer, Daniel Franz
Institut für Anatomie
Zuber, Benoîtorcid-logo
Institut für Anatomie
Gnägi, Helmut
Lin, Fang
Subject(s)

600 - Technology::610...

Series
Microscopy research and technique
ISSN or ISBN (if monograph)
1059-910X
Publisher
Wiley-Liss
Language
English
Publisher DOI
10.1002/jemt.22397
PubMed ID
25045045
Uncontrolled Keywords

freeze fracture

high-pressure freezin...

CEMOVIS

thermotropic

lyotropic

Description
Liquid crystals (LCs) represent a challenging group of materials for direct transmission electron microscopy (TEM) studies due to the complications in specimen preparation and the severe radiation damage. In this paper, we summarize a series of specimen preparation methods, including thin film and cryo-sectioning approaches, as a comprehensive toolset enabling high-resolution direct cryo-TEM observation of a broad range of LCs. We also present comparative analysis using cryo-TEM and replica freeze-fracture TEM on both thermotropic and lyotropic LCs. In addition to the revisits of previous practices, some new concepts are introduced, e.g., suspended thermotropic LC thin films, combined high-pressure freezing and cryo-sectioning of lyotropic LCs, and the complementary applications of direct TEM and indirect replica TEM techniques. The significance of subnanometer resolution cryo-TEM observation is demonstrated in a few important issues in LC studies, including providing direct evidences for the existence of nanoscale smectic domains in nematic bent-core thermotropic LCs, comprehensive understanding of the twist-bend nematic phase, and probing the packing of columnar aggregates in lyotropic chromonic LCs. Direct TEM observation opens ways to a variety of TEM techniques, suggesting that TEM (replica, cryo, and in situ techniques), in general, may be a promising part of the solution to the lack of effective structural probe at the molecular scale in LC studies. Microsc. Res. Tech. 77:754-772, 2014. © 2014 Wiley Periodicals, Inc.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/126616
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
jemt22397.pdftextAdobe PDF1.86 MBpublisherpublished restricted
LC-TEM-MinGao-revised-5-10-2014.pdftextAdobe PDF4.21 MBpublisheracceptedOpen
BORIS Portal
Bern Open Repository and Information System