• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. O-Ring Attachments on One-Piece Mini Dental Implants: In-Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations.
 

O-Ring Attachments on One-Piece Mini Dental Implants: In-Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.153460
Publisher DOI
10.11607/ijp.7055
PubMed ID
33625384
Description
PURPOSE

To analyze the influence of pristine matrix and O-ring dimensions on retention force and reproducibility in single one-piece mini dental implants (MDIs) with ball patrices under in vitro conditions.

MATERIALS AND METHODS

Three different matrix and O-ring combinations (MH1-MH3) were evaluated (n = 50 per group) on 1.8-mm-diameter implants. The matrices were manually mounted on the implants and were subsequently removed in a vertical linear manner using a metal pin with two strain gauges, recording the maximum force during disconnection. After five disconnections, the O-rings were exchanged, and the mean retention force was calculated, resulting in 50 values for each matrix and O-ring combination. Mean retention forces, SDs, and 95% CI were calculated. Analysis of variance was used to test the global differences, and post hoc pairwise comparisons were subsequently applied. The level of significance was set to P < .05.

RESULTS

ANOVA (global P < .0001) and pairwise comparisons (all P < .0001) demonstrated statistically significant differences among the three different matrix and O-ring combinations, with mean values of 5.18 N (MH 1), 6.73 (MH 2), and 9.08 (MH 3). Within each combination, retention force variations of > 1 N could not be demonstrated; ie, by exchanging O-rings, a similar retention force can be reestablished.

CONCLUSION

Matrix and O-ring dimensions have a significant influence on retention forces in one-piece MDIs. Pristine O-rings demonstrated highly reproducible initial retention forces in all matrices.
Date of Publication
2023
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Abou-Ayash, Samir
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Schimmel, Martinorcid-logo
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Worni, Andreas
Enkling, Norbert
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
The international journal of prosthodontics
Publisher
Quintessence Publishing
ISSN
1942-4426
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo