• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Hard and soft tissue evaluation of titanium dental implants and abutments with nanotubes in canines.

Hard and soft tissue evaluation of titanium dental implants and abutments with nanotubes in canines.

Details
Files
DOI
10.7892/boris.137664
Publisher DOI
10.1002/JPER.18-0205
PubMed ID
31490010
Abstract
BACKGROUND

Little is known regarding the interaction of dental implant surface nanotubes and oral soft and hard tissues. The purpose of this study was to evaluate both histologically and radiographically the qualitative and quantitative effects of dental implant surface nanotubes on hard and soft tissue in a canine model.

METHODS

Three subgroups consisting of a combination of test and control implants and abutments (Group A: control implant/control abutment, Group B: control implant/test abutment: Group C: test implant/test abutment) were placed in edentulous mandibles of six large-breed canines. Implants and abutments were placed on one side at baseline, and on the opposite side of the mandible at week 10; sacrifice occurred at week 12. Quantitative and qualitative analyses were used to measure newly formed hard and soft tissues histologically and radiographically.

RESULTS

The mean radiographic change in marginal bone level from weeks 0 to 12 between implant groups was not statistically significant (P > 0.05). Mean soft tissue contact (junctional epithelium + connective tissue) for Groups A, B, and C were 2.29, 2.33, and 2.31 mm, respectively, with no statistically significant difference (P > 0.05) between the groups. All connective tissue fibers were oriented parallel to the abutment regardless of surface treatment.

CONCLUSIONS

The findings of this study suggest that healing of hard and soft tissues around implants and abutments is similar when comparing grit-blasted surfaces to machined, turned surfaces with nanotubes. Both resulted in similar soft tissue contact values, as well as connective tissue fiber orientation.
Date Issued
2020-04
Publication Type
Article
Subject(s)
600 Technology
600 Technology > 610 Medicine & health
Subjects
dental implant dental implant abutment design dental implant abutment interface nanotube
Language(s)
en
Author(s)
Garrett, Phillip W
Johnston, Gary W
Bosshardt, Dieter  
Zahnmedizinische Kliniken, Forschung Oralchirurgie  
Jones, Archie A
Sasada, Yuya
Ong, Joo L
Cochran, David L
Additional Credits
Zahnmedizinische Kliniken, Forschung Oralchirurgie  
Journal
Journal of periodontology
Publisher
American Academy of Periodontology
ISSN
0022-3492
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify